Event Notification
N-Tron
®
Series NT24K
®
Software Manual
2-49
2.16.1.2
Event
Log
Filter
Modify
The Event Log Filter configuration can be changed by clicking on the Modify button.
Quick Configure:
Use Quick Configure to change all components to the same severity level.
Component
: The feature, protocol, or system service of the switch that generates events. The component list
is model dependent.
Minimum Severity:
Events below the minimum severity level will not be logged. A severity of None will disable
events for that component. For more information, see Severity under section
.
2.16.2
Syslog
The Syslog feature allows certain system events (see Event Log) to be sent as messages to remote hosts for
monitoring and analysis.
The messages can be sent to up to 5 different remote hosts, known as Syslog Collectors. A minimum severity level
is associated with each Syslog Collector. Events below the minimum severity level will not be sent out from the