MODE 4  OUTPUT 1 TURN OFF AT PRESET 2, TIMED OUTPUT 2 AT PRESET 2,

AUTOMATIC RESET TO ZERO AT PRESET 2

In this mode, as the unit counts from zero, output 1 will turn on

when preset 1 is reached. When preset 2 is reached, output 2 will
turn on, output 1 will turn off, and the unit will automatically Reset
to Zero. Output 2 will turn off after its programmed time value has occurred.
Manual reset

will turn off both outputs, if activated, and reset the count to

zero. During automatic reset, no counts will be lost as long as the count rate
does not exceed 2,500 cps.

MODE 5  TIMED OUTPUTS AT PRESETS, AUTOMATIC RESET TO ZERO AT PRESET 2

In this mode, as the unit counts from zero, output 1 will turn on

when preset 1 is reached and output 2 will turn on when preset 2 is
reached.  The  outputs  will  turn  off  after  their  respective
programmed time values have occurred. Also, when preset 2 is reached, the
unit will automatically reset the count to zero and start the cycle over. 

(Output

2 will remain on until its time value has occurred.)

Manual reset

will turn off

both  outputs  and  reset  the  count  to  zero.  During  automatic  reset,  no  counts
will be lost, as long as the count rate does not exceed 2,500 cps.

MODE 6  OUTPUT 1 TURN OFF AT PRESET 2, TIMED OUTPUT 2 AT PRESET 2,

AUTOMATIC RESET TO ZERO AFTER TIMED OUTPUT 2

In this mode, as the unit counts from zero, output 1 will turn on

when preset 1 is reached. When preset 2 is reached, output 2 will
turn on and output 1 will turn off. Output 2 will turn off after its
programmed time value has occurred. At the end of timed output 2, the unit
will  automatically  Reset  to  Zero  and  start  the  cycle  over  again.  During
automatic  reset,  no  counts  will  be  as  lost  as  long  as  the  count  rate  does  not
exceed 2,500 cps. Manual reset

will turn off both outputs, if turned on, and

reset the count to zero.

MODE 7  TIMED OUTPUTS AT PRESETS, AUTOMATIC RESET TO ZERO AFTER TIMED

OUTPUT 2 

In this mode, as the unit counts from zero, output 1 will turn on

when preset 1 is reached and output 2 will turn on when preset 2 is
reached.  The  outputs  will  turn  off  after  their  respective
programmed time values have occurred. At the end of timed output 2, the unit
will  automatically  Reset  to  Zero  and  start  the  cycle  over  again.  During
automatic  reset,  no  counts  will  be  lost,  as  long  as  the  count  rate  does  not
exceed 2,500 cps. Manual reset

will turn off both outputs, if turned on, and

reset the count to zero.

MODE 8  LATCH OUTPUT AT PRESET 1 AND ZERO, MANUAL RESET TO PRESET 2 

In this mode, as the unit counts from preset 2, output 1 will latch

on when preset 1 is reached and output 2 will latch on when zero
is  reached.  When  a  manual  reset

occurs,  the  unit  will  Reset  to

Preset  2  and  the  output,  if  latched  on,  will  unlatch.  Counts  will  continue  to
register after the outputs have turned on.

MODE 9  TIMED OUTPUT AT PRESET 1 AND ZERO, MANUAL RESET TO PRESET 2 

In this mode, as the unit counts from preset 2, output 1 will turn

on when preset 1 is reached and output 2 will turn on when zero is
reached.  The  outputs  will  turn  off  after  their  respective
programmed  time  values  have  occurred.  When  a  manual  reset

occurs,  the

unit will Reset to Preset 2. Manual reset will terminate the timed outputs, if
the  outputs  are  still  activated.  Counts  will  continue  to  accumulate  after  the
outputs have activated.

When down count is desired, (such as reset to preset modes of operation)

the “UP/DN” terminal must be tied to the “COMM.” terminal

.

Manual reset, either by front panel reset (if enabled) or remote reset, is always

active, and will override any condition or state the counter is presently in.

MODE 10  OUTPUT 1 TURN OFF AT ZERO, LATCH OUTPUT 2 AT ZERO, MANUAL

RESET TO PRESET 2 

In this mode, as the unit counts from preset 2, output 1 will turn

on when preset 1 is reached. When zero is reached, output 2 will
turn on and output 1 will turn off. Output 2 will remain latched on
until a manual reset occurs. Counts will continue to accumulate after preset
levels have been reached. Manual reset

will turn off all outputs if activated

and the unit Resets to Preset 2.

MODE 11  OUTPUT 1 TURN OFF AT ZERO, TIMED OUTPUT 2 AT ZERO, MANUAL

RESET TO PRESET 

In this mode, as the unit counts from preset 2, output 1 will turn

on when preset 1 is reached. When zero is reached, output 2 will turn
on  and  output  1  will  turn  off.  Output  2  will  turn  off  after  its
programmed time value has occurred. Counts will continue to accumulate after
preset  levels  have  been  reached.  When  a  manual  reset

occurs,  the  unit  will

Reset to Preset 2. Manual reset will also turn off both outputs, if still activated.

MODE 12  OUTPUT 1 TURN OFF AT ZERO, TIMED OUTPUT 2 AT ZERO, AUTOMATIC

RESET TO PRESET 2 AT ZERO 

In this mode, as the unit counts from preset 2, output 1 will turn

on when preset 1 is reached. When zero is reached, output 2 will
turn on, output 1 will turn off, and the unit will automatically Reset
to  Preset  2.  Output  2  will  turn  off  after  its  programmed  time  value  has
occurred. Manual reset

will turn off both outputs, if turned on, and reset the

count to preset 2. During automatic reset, no counts will be lost if the count
rate does not exceed 2,500 cps.

MODE 13  TIMED OUTPUTS AT PRESET 1 AND ZERO, AUTOMATIC RESET TO

PRESET 2 AT ZERO 

In this mode, as the unit counts from preset 2, output 1 will turn

on when preset 1 is reached and output 2 will turn on when zero is
reached. The outputs will turn off after their respective programmed
time  values  have  occurred.  Also,  when  zero  is  reached,  the  unit  will
automatically reset the count to preset 2 and start the cycle over. 

(Output 2 will

remain on until its time value has occurred.)

Manual reset

will turn off both

outputs, if turned on, and reset the count to preset 2. During automatic reset, no
counts will be lost, as long as the count rate does not exceed 2,500 cps.

MODE 14  OUTPUT 1 TURN OFF AT ZERO, TIMED OUTPUT 2 AT ZERO, AUTOMATIC

RESET TO PRESET 2 AFTER TIMED OUTPUT 2 

In this mode, as the unit counts from preset 2, output 1 will turn

on when preset 1 is reached. When zero is reached, output 2 will
turn on and output 1 will turn off. Output 2 will turn off after its
programmed time value has occurred. At the end of timed output 2, the unit
will automatically Reset to Preset 2 and start the cycle over. During automatic
reset, no counts will be lost, as long as the count rate does not exceed 2,500
cps. Manual reset

will turn off both outputs, if activated, and reset the count

to preset 2.

MODE 15  TIMED OUTPUTS AT PRESET 1 AND ZERO, AUTOMATIC RESET TO

PRESET 2 AFTER TIMED OUTPUT 2 

In this mode, as the unit counts from preset 2, output 1 will turn

on when preset 1 is reached and output 2 will turn on when zero is
reached.  The  outputs  will  turn  off  after  their  respective
programmed time values have occurred. At the end of timed output 2, the unit
will automatically Reset to Preset 2 and start the cycle over. During automatic
reset, no counts will be lost, as long as the count rate does not exceed 2,500
cps. Manual reset

will turn off either output, if turned on, and reset the count

to preset 2.

MODES OF OPERATION FOR DUAL PRESET LIBRA COUNTER (Cont’d)

The  selection  of  Input  Set-up  and  Modes  of  Operation  is  accomplished  by

eight  DIP  switches,  located  at  the  rear  of  the  unit,  in  the  upper  right-hand
corner. DIP switches 1 to 3 are used to configure the input, and DIP switches 5
to  8  are  used  to  determine  the  modes  of  operation.  DIP  switch  4  is  used  to
enable or disable the front panel reset button. The input set-up and reset enable
switches will be discussed first. Refer to the block diagram of the unit for the
details of count and control circuitry.

SWITCH SET-UP

S1 - SNK:

Provides a 7.8 K

pull-up resistor for sensors with sinking outputs.

SRC:

Provides  a  3.9  K

pull-down  resistor  for  sensors  with  sourcing

outputs.

S2 - HI FRQ:

Removes damping capacitor and allows operation up to 2.5 KHz.

Minimum count OFF times - 50 µsec.

LO FRQ:

Connects damping capacitor for switch contact debounce. Limits

count speed to 100 Hz. Minimum count pulses ON/OFF times - 5 msec.

S3 - HI BIAS:

Sets input trigger levels at mid-

range  to  accept  outputs  from  2-wire
proximity  sensors,  resistive  photo-cells,
and  logic  pulses  with  full  0  to  +12  V
swings. (V

IL

= 5.5 V, V

IH

= 7.5 V)

LO  BIAS:

Sets  input  trigger  levels  to  the

low range to accept logic pulses with 0 to 5
V swings. (V

IL

= 1.5 V, V

IH

= 3.75 V)

S4 - DIS RST:

Disables front panel reset.

EN RST:

Enables front panel reset.

SELECTION OF INPUT SET-UP & MODES OF OPERATION

LIBC-j.QXD  10/26/04 10:52 AM  Page B4

Summary of Contents for LIBC Series

Page 1: ...unit s timed output is set at the factory to be 0 1 sec The Libra counters have an internal non volatile memory device which eliminates the need for battery back up When input power is removed this de...

Page 2: ...contacts max rating 5 amps 120 240 VAC 28 VDC resistive load 1 8 H P 120 VAC inductive load The operate time is 5 msec nominal and the release time is 3 msec nominal Relay Life Expectancy 100 000 cyc...

Page 3: ...t will automatically Reset to Preset and start the cycle over During automatic reset no counts will be lost as long as the count rate does not exceed 2 500 cps Manual reset will turn off the output if...

Page 4: ...OUTPUT 1 TURN OFF AT ZERO TIMED OUTPUT 2 AT ZERO MANUAL RESET TO PRESET In this mode as the unit counts from preset 2 output 1 will turn on when preset 1 is reached When zero is reached output 2 will...

Page 5: ...t that is properly grounded This is especially useful in applications where cable runs are long and portable two way radios are used in close proximity or if the installation is near a commercial radi...

Page 6: ...ressing and holding the button will continuously scroll the digit from 0 through 9 then back to 0 again When the desired value for that digit is reached release the button Do this for all the digits t...

Page 7: ...nters meet NEMA 4 IP65 requirements for indoor use when properly installed The units are intended to be mounted into an enclosed panel with a gasket to provide a water tight seal Two mounting clips an...

Page 8: ...requirement exists to control a solenoid which places a red ink marking at the end of a roll of printing paper this marking is used to indicate when the end of the roll is near The unit must also sto...

Reviews: