PERFORMS HIERARCHICAL CONTROL OF OTHER MODULES

IN THE MODULAR CONTROLLER SERIES

z

PROVIDES POWER AND COMMUNICATIONS TO MODULES

THROUGH BACKPLANE CONNECTOR

z

STORES MODULE CONFIGURATION INFORMATION, AND

AUTOMATICALLY REPROGRAMS REPLACED MODULES

z

EXTENSIVE BUILT-IN DRIVER LIST ALLOWS EASY DATA

MAPPING TO PLCs, PCs, AND SCADA SYSTEMS

z

INDEPENDENT SERIAL PORTS PROVIDE VIRTUALLY

UNLIMITED INTEGRATION METHODS

z

10 BASE-T/100 BASE-TX ETHERNET CONNECTION PROVIDES

NETWORKING CAPABILITY

z

SUPPORTS UP TO 16 MODULAR CONTROLLER SERIES

MODULES

z

SUPPORTED BY CRIMSON 2.0 SOFTWARE (OLDER CRIMSON

1.0 FILES MAY BE IMPORTED INTO CRIMSON 2.0)

GENERAL DESCRIPTION

The Model CSMSTRV2 is a communications and control platform designed

for use with Modular Controller Series slave modules. The CSMSTRV2 uses a
proprietary high speed serial protocol to communicate, via backplane
connection, with up to 16 slave modules. Through the same connection, the
Master also provides power to the modules. 

When powered up, the CSMSTRV2 automatically identifies and addresses

connected slave modules. By storing the configuration information of all of the
modules, the CSMSTRV2 is able to automatically configure modules if they are
replaced.

The Master provides high-speed RS232/422/485 communication ports and an

Ethernet port for connection to PCs, PLCs, and SCADA systems. An extensive
list of master and slave protocol drivers are available to allow the CSMSTRV2
to share and exchange variable data with external devices. The 10 Base-T/100
Base-TX Ethernet port can also be used to connect and share data with other
devices at high speeds. 

The CSMSTRV2 was designed as a direct replacement for the original

CSMSTRSE. This new model provides benefits such as support via Crimson 2.0
software, which allows configuration files to be uploaded. To save programming
time, files originally created in Crimson 1.0 (.cdb files) may be imported into
Crimson 2.0.

The design of the Modular Controller Series high density packaging and DIN

rail mounting saves time and panel space. The controller snaps easily onto
standard top hat (T) profile DIN rail.

SOFTWARE

The CSMSTRV2 is programmed with Crimson 2.0 software for Windows

®

2000 or later platforms. The software is an easy to use, graphical interface which
provides a means of communication configuration, as well as commissioning
and calibration of new systems.

CONTENTS OF PACKAGE

- CS Master
- Termination Plug
- Terminal Block for connecting power.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

Do not use the controller to directly command motors, valves, or other

actuators not equipped with safeguards. To do so can be potentially harmful to
persons or equipment in the event of a fault to the controller. An independent and
redundant temperature limit indicator with alarm outputs is strongly
recommended.

MODEL CSMSTRV2 – MODULAR CONTROLLER SERIES MASTER

Bulletin No.  CSMSTRV2-A
Drawing No.  LP0641
Released  11/06

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

CAUTION: Risk of Danger.

Read complete instructions prior to installation

and operation of the unit.

DIMENSIONS  In inches (mm)

C

US LISTED

US LISTED

UL

R

IND. CONT. EQ.

34AD

Summary of Contents for CSMSTRV2-A

Page 1: ...share data with other devices at high speeds The CSMSTRV2 was designed as a direct replacement for the original CSMSTRSE This new model provides benefits such as support via Crimson 2 0 software whic...

Page 2: ...and Laboratory use Notes 1 Criterion A Normal operation within specified limits 2 This device was designed for installation in an enclosure To avoid electrostatic discharge to the unit in environments...

Page 3: ...ly not more than 6 feet 1 8 m of cable between the supply and the master Ideally the shortest length possible should be used The wire used to connect the master s power supply should be at least 22 ga...

Page 4: ...h ground protective earth at one end where the unit is mounted b Connect the shield to earth ground at both ends of the cable usually when the noise source frequency is over 1 MHz c Connect the shield...

Page 5: ...walkeremd com Standard Ethernet cable Use appropriate communications cable See Ordering Information for descriptions of the available cables WARNING Do NOT use a standard DH 485 cable to connect this...

Page 6: ...or permanent connection ETHERNET COMMUNICATIONS Ethernet communications can be established at either 10 BASE T or 100 BASE TX The Master s RJ45 jack is wired as a NIC Network Interface Card For exampl...

Page 7: ...One or more slave modules are missing from the system Master and installed modules will perform normally in this state INDICATION 2 blinks pause repeat Missing configuration or configuration being upd...

Page 8: ...or products containing components manufactured by RLC and based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be...

Reviews: