N-Tron
®
Series 700/7000 Managed Industrial Ethernet Switch Hardware Manual - Volume I
1-19
Product Overview
Revised 2019-08-22
716M12
Drawing No. LP0988
1.8.2
716M12
Specifications
* High Voltage - HV option
Mechanical
Height
Width
Depth
Weight
Mount
6.7" (16.9 cm)
6.7" (16.9 cm)
2.2" (5.6 cm)
4.6 lbs (2.1 kg)
35mm DIN-Rail
(Optional)
Power Input
Input Voltage
Steady Input Current
Inrush Current
BTU/hr
10-49 VDC
(Regulated)
350 mA @ 24 VDC
18.0 A /0.1 ms @ 24
VDC
28.7 @ 24 VDC
40-160 VDC
(Regulated)*
73 mA @ 124 VDC*
30.9 @ 124 VDC*
Environmental
Operating
Temperature
Storage Temperature Operating Humidity
Operating Altitude
-40 °C to 85 °C
-40 °C to 80 °C (HV)
-40 °C to 85 °C
5% to 100% (non condensing)
0 to 10,000 ft.
Shock and Vibration
Shock
Vibration
Note
200g @ 10 ms
50g, 5-200Hz, Triaxial
Unit must be bulkhead mounted to achieve these
levels.
Connectors
10/100BaseTX: 16 M12 D Coded Female Copper Ports
POWER: One M12 A Coded Male Port
COM: One M12 A Coded Female CLI Port
NTCD-M12: One M12 A Coded Female
Configuration Device Port
Pin Assignments
Recommended Minimum Wiring Clearance
Front
4” (10.16 cm)
Network Media
10BaseT
100BaseTX
≥CAT3 Cable
≥CAT5 Cable
Switch Properties
Number of MAC Addresses
Aging Time
Latency (Typical)
Switching Method
8,000
Programmable
2.9 µs
Store & Forward