Introduction
Specifications
10
Specifications
Table 2 shows the adjustable pump lengths by model
Table 3 shows pump electrical service requirements.
Table 4 lists UMP weights and lengths.
The weights and lengths listed below are approximate values and will vary due to
manufacturing tolerances.
The optional trapper intake screen is available as a field installed accessory. Trapper options will increase the
length of the UMP by 3.3 inches (83 mm). For installation instructions, see Red Jacket installation instructions
#051-256-1. For models with floating suction adapter, add 2-3/8 inches (59 mm) and 4 pounds (1.8 kg).
Table 2. Distances From Top Of Lifting Screw To Inlet
Model#
Retracted
Extended
in.
mm
in.
mm
P200U20-2RJ1
75
1902
105.5
2673
P200U20-2RJ2
105
2665
165.5
4197
P200U20-2RJ3
165
4188
225.5
5721
Table 3. Electrical Service Information
Required power supply rating for 60 Hz, 1 phase is 208 - 230 Vac. For 50 Hz, 1 phase, required rating is 220 - 240 Vac. For
3 phase, required rating is 200 - 240 Vac.
UMP Model No.
HP
Hz
PH
Voltage Fluctuation
Range
Max.
Load
Amps
Locked
Rotor
Amps
Winding Resistance (Ohms)
Min.
Max.
Black-
Orange
Red-
Orange
Black-Red
UMP200U20-2
2
60/50
1
180
265
16
–
2.0 - 3.0
2.0 - 3.0
2.0 - 3.0
60/50
3
10
–
Table 4. UMP Model Dimensions
A
(Use these lengths for UMPs with
end view A shown in Figure 5)
B
(Use these lengths for UMPs with
end view B shown in Figure 5)
Weight
UMP Model
HP
in.
mm
in.
mm
lb.
kg
UMP200U20-2
2
20
508
20¾
527
37
16.8
NOTICE