Red Jacket Quick-Set AGUMP150S1 Replacement Instructions Manual Download Page 16

UMP Replacement Instructions

Replacing the UMP for the Standard STP

13

7.

Lift out the extractable unit allowing the pump to drain into the tank before complete extraction.

DO NOT damage the surface above the discharge port. The o-ring below the leak 
detector port seals on this surface.

Before replacing the extractable portion, make sure that the packer o-ring and discharge o-
ring seal surfaces are clean. New o-rings should be installed, lubricate with petroleum jelly.

8.

Place the unit on a clean surface

9.

Remove the old UMP by removing the four bolts holding the discharge head as shown in Figure 7. Discard the 
old gasket and fasteners.

10. Visually inspect the pigtail connector in the discharge head - replace if damaged. Be certain the indexing tab 

of the pigtail is seated in the notch of the discharge head.

Figure 7.   UMP Bolts And Gasket

11. Pull the pigtail connector in the discharge head out far enough to see the o-ring in the sidewall of its socket 

(see Figure 8). Remove the connector’s o-ring from the connector’s socket and discard it. After referring to the 
instructions in the Discharge Head O-ring Kit, select the correct o-ring from the kit and lubricate it with 
petroleum jelly. Slide the new o-ring over the pigtail connector and push it in the groove in the wall of the 
connector’s socket. Lubricate the pigtail connector body with petroleum jelly and push it back into its socket, 
making sure its index tab is in the socket’s notch.

12. Place the new gasket from the UMP replacement kit on the new UMP so that all the holes align.

Gaskets from competitive UMPs will not seal properly and performance will be 
reduced. 

CAUTION

NOTICE

053-1

Gasket

Fasteners (4)

CAUTION

Summary of Contents for Quick-Set AGUMP150S1

Page 1: ...Manual No 577014 053 Revision D Replacement Instructions Red Jacket UMP Red Jacket Quick Set Submersible Pump...

Page 2: ...f any damages and or shortages within 30 days of receipt of the shipment as stated in our Terms and Conditions VEEDER ROOT S PREFERRED CARRIER 1 Fax Bill of Lading to V R Customer Service at 800 234 5...

Page 3: ...gure 7 UMP Bolts And Gasket 13 Figure 8 Verifying Pigtail s Female Connector Is Seated Properly In Discharge Head 14 Tables Table 1 Maximum Specific Gravity And Maximum Viscosity 4 Table 2 Electrical...

Page 4: ...Turn Off power to the device and associ ated accessories when servicing the unit WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION indicates...

Page 5: ...re your employees and any service contractors read and follow the instructions Follow the Regulations Applicable information is available in National Fire Protection Association NFPA 30A Code for Moto...

Page 6: ...er s station WILL NOT shut off electrical power to the pump dispenser This means that even if you press a button on the console labeled EMERGENCY STOP ALL STOP PUMP STOP or something similar fuel may...

Page 7: ...ted for the following fuel compatibility 100 Diesel 100 Gasoline Gasoline and up to 10 Ethanol 15 Methanol 20 MTBE 20 ETBE 20 TAME All models of The Red Jacket with the AG prefix are UL Listed for the...

Page 8: ...144 224 5 17 5 AGUMP75S1 UMP75U1 3 4 60 1 200 250 6 5 25 2 9 3 6 14 9 18 2 17 7 21 9 410164 001 17 5 AGUMP150S1 UMP150U1 1 1 2 60 1 200 250 10 5 37 2 0 2 5 11 6 14 2 13 5 16 8 410164 002 25 X3AGUMP15...

Page 9: ...1 1 2 60 1 200 250 10 5 33 2 8 3 4 6 8 8 2 9 4 11 3 410164 002 25 AGUMP200S1 3 AGUMPL200S1 3 UMP200U1 3 UMPL200U1 3 2 60 1 200 250 11 4 44 1 9 2 3 3 4 4 1 5 1 6 2 410164 003 40 AGUMP75S3 3 UMP75U3 3 3...

Page 10: ...8 505 30 5 13 9 UMP75U17 3 AGUMP75U17 3 3 4 19 1 4 489 19 483 28 12 7 UMP150U1 AGUMP150S1 1 1 2 20 1 2 519 20 5 8 524 34 15 5 X3P150U1 X3AGUMP150S1 1 1 2 21 1 4 540 21 1 2 546 35 15 8 UMP150U3 3 AGUMP...

Page 11: ...d down line from the pump close it 2 Remove the two extractable lock down nuts and discard them see Figure 2 The springs on the lock down studs between the extractable s flange and the manifold will p...

Page 12: ...inding occurs during removal stop and determine the cause of the binding and correct the situation before proceeding with removal For all models with the RA suffix take care not to damage the powder c...

Page 13: ...UMP retaining bolts Use hand force to push the UMP onto the discharge head If the UMP does not seat snug against the discharge head remove the UMP and correct the problem Fasteners are not metric use...

Page 14: ...nd in the kit Apply anti seize also found in the kit to the lock down studs prior to nut and washer installation 15 Turn the air purge screw 2 3 turns counterclockwise see Figure 2 The air purge screw...

Page 15: ...ssure to flow into the tank or back out Functional Element screw Confirm that the packer wiring compartment cover plug with lifting eyebolt is properly torqued at 50 ft lbs 70 N m Confirm that the lif...

Page 16: ...indexing tab of the pigtail is seated in the notch of the discharge head Figure 7 UMP Bolts And Gasket 11 Pull the pigtail connector in the discharge head out far enough to see the o ring in the sidew...

Page 17: ...nt 15 Replace the packer o ring and discharge Quad seal after lubricating them with petroleum based jelly 16 Reinstall the extractable portion into the tank aligning the positioning dowels of the mani...

Page 18: ...ressure at line test port 50 psi 345 kPa maximum Excessive pressure above normal test pressure of 50 55 psi 345 380 kPa may damage check valve seat and other system components 4 After completion of li...

Page 19: ...For technical support sales or other assistance please visit www veeder com...

Reviews: