Conforms to ANSI Z21.97-2014/CSA STD 2.41-2014

Outdoor Decorative Gas Appliances 

1

US

R

C

R

R

OWNER’S MANUAL

Red Ember Willow Aluminum Square Propane Gas Fire Pit Table/
Red Ember Juneau 44 in. Square Aluminum Fire Pit
SKU WTL257-1/WTL302-1
Supplier Item #: 62404/62416

   

WARNING

This product can expose you to chemicals 
including carbon monoxide which is known to the 
State of California to cause birth defects or other 
reproductive harm. For more information go to  
www.P65Warnings.ca.gov.

Summary of Contents for WTL257-1

Page 1: ...e Propane Gas Fire Pit Table Red Ember Juneau 44 in Square Aluminum Fire Pit SKU WTL257 1 WTL302 1 Supplier Item 62404 62416 WARNING This product can expose you to chemicals including carbon monoxide which is known to the State of California to cause birth defects or other reproductive harm For more information go to www P65Warnings ca gov ...

Page 2: ...racket 1 J Gas Tank Support 1 1 K L Bolt 8 60mm Nut M8 Washer Spring Washer 4 M Bolt 6 25mm Washer M6 8 1 N 1 O P Allen Wrench Glass Beads 1 Q 2boxes 4bags A B C D E Protective Fire Pit Cover R 1 Connecting Rod Door Frame S 1 E G F H I J Guard Bar K Table Top Burner Burner Bracket Side Panel 1 Side Panel 2 Screwdriver Wrench T 4 Bolt 6 22mm Washer M6 ...

Page 3: ...ances CGA CR 97 003 Outdoor Gas Fireplaces The installation must conform to local codes or in the absence of local codes to the National Fuel Gas Code ANSIZ223 1 This manual contains important information about the assembly operation and maintenance of this fire pit General safety information is presented in these first few pages and is also located throughout the manual Keep this manual for futur...

Page 4: ... and heat producing products for specific uses Your local authorities can advise you about these If no local codes exist follow National Fuel Gas Code ANS Z223 1 In Canada installation must conform to local codes If no local codes exist follow the current National standards of CANADA CAN CGA B 149 2 DANGER WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity o...

Page 5: ...the original leak Use only propane gas set up for vapor withdrawal ordinances and codes or with ANS NFPA 58 Turn off propane when not in use WARNING temperatures Stay away from these surfaces to avoid burning skin or igniting clothing of the fire pit from the fire pit or place on or near the fire pit servicing the appliance prior to placing back in service service person The fire pit should be ins...

Page 6: ...Bracket J to Side Panel 1 E and Side Panel 3 G by aligning holes in the Gas Tank Bracket with those found at the bottom of the Side Panels Insert Bolt 6 22mm through Washer T and through holes Tighten with Allen Wrench P Then slide the ends of the Gas Tank Support K onto the right side of the Gas Tank Bracket J and align the 2 holes on the front of the Gas Tank Support K with the 2 holes at the bo...

Page 7: ...ote The Control Knob is located on the end of the Connecting Rod and will be used for operation of the burner 4 L Bolt 8 60mm Hardware Used x 4 Washer Spring washer Nut M8 O N 4 Affix the Bolts 8 60mm L to the underside of the Table Top B with the Screwdriver N Then turn the Table Top over and align the Bolts with the holes in the assembled panels Place the Table Top on the assembled panels so the...

Page 8: ...ld have this book Storage of an appliance indoors is permissible only if the cylinder is disconnected and removed from the appliance A cylinder must be stored outdoors in a well ventilated area out of reach of children A disconnected cylinder must have dust caps tightly installed and must not be stored in a building garage or any other enclosed area The maximum inlet gas supply pressure 250 psi Th...

Page 9: ... to the heater Attach regulator to cylinder Complete attachment Install cylinder Do not store a spare LP gas cylinder under or near this appliance Never fill the cylinder beyond 80 percent full Place the dust cap on the cylinder valve outlet whenever the cylinder is not in use Only install the type of dust cap on the cylinder valve that is provided with the cylinder valve Other type of caps or plu...

Page 10: ...Underside of burner 10 NEVER perform a leak test when smoking ...

Page 11: ...11 11 ...

Page 12: ...ced efficiency below 40F 7 Fire pit is outdoors outside any enclosure 8 There is adequate fresh air ventilation When fire pit is ON Burner will display tongues of blue and yellow flame These flames should not be yellow or produce thick black smoke indicating an obstruction of airflow through the burners The flame should be blue with straight yellow tops If excessive yellow flame is detected turn o...

Page 13: ... before use and at least annually by a qualified service person 21 More frequent cleaning may be required as necessary It is imperative that control compartment burner and circulating air passageways of the fire pit be kept clean After Operation 1 Gas control is in OFF position 2 Gas Tank valve is OFF 3 Disconnect Gas line WARNING FOR YOUR SAFETY fire pit for at least 45 minutes after use To enjoy...

Page 14: ...Caution Always allow fire pit to cool before attempting service 14 ...

Page 15: ...15 ...

Page 16: ...RANTIES EXCEPT AS LISTED ABOVE PURCHASER ASSUMES ALL RISKS IN THE ASSEMBLY AND OPERATION OF THIS UNIT FAILURE TO FOLLOW WARNINGS AND OPERATIONAL INSTRUCTIONS CONTAINED IN THIS MANUAL CAN RESULT IN SEVERE PROPERTY DAMAGE AND OR PERSONAL INJURY IN NO EVENT WILL THE MANUFACTURER OR ITS DIRECTORS OFFICERS OR AGENTS BE LIABLE TO THE PURCHASER OR ANY THIRD PARTY WHETHER IN CONTRACT IN TORT OR ON ANY OTH...