Always check unit before applying power (see Sections 6-1 thru 6-18).
TM-229 409 Page 44
Extreme 360
6-27. Power Interconnect Board PC2 Testing Information (Use with Section 6-28)
Ref. 225 065-A / 907 161
Y
Warning this procedure
requires the machine to be
electrically live. Signifi-
cant DC voltage can
remain on capacitors after
unit is Off.
Be sure plugs are secure before
applying power. See Section
6-28 for specific values during
testing.
1
Power Interconnect Board
PC2
2
Receptacle RC1
3
Receptacle RC2
4
Receptacle RC3
5
Receptacle RC6
6
Receptacle RC7
Test Equipment Needed: