PRE-POWER CHECKS
TM-229 409 Page 21
Extreme 360
6-6. Inverter Module (MOD2)
Ref. 907 161 / 225 065-A
Y
Read and follow safety
before proceeding.
Y
Wear an earth grounded
wrist strap when performing
pre-power checks. Remove
wrist strap before perform-
ing any checks or proce-
dures with power applied to
the machine.
.
Board layout may differ from
that shown.
1
MOD2
Visually inspect MOD2 for damage.
2
−
BUS
3
TP2
4
TP1
5
L2
6
TP4
7
HF-XFMR
8
D4
9
D2
10 TP3
11 D8
12 D10
13 D11
14 +BUS
Check all measurements for Invert-
er Module (MOD2) (see Section
6-7).
If all measurements passed, MOD2
is OK. Continue to the end of the
pre
−
power flowchart (see Section
6-2).
1
Component Side Of Board
7
10
5
14
2
4
6
9
11
12
13
Test Equipment Needed:
3
8
6-7. Inverter Module (MOD2) Test Point Values
Inverter Module MOD2
DVM Positive Lead
DVM Negative Lead
DVM Diode
DVM Ohms
Boost Snubber Diode
TP1 (C6 and C7)
TP4 (C1)
0.20 - 0.90
N/A
Boost Snubber Diode
L2
TP4 (C1)
0.20 - 0.90
N/A
Main Boost Diode
TP4 (C1)
+BUS
0.20 - 0.90
N/A
Inverter IGBT
HF-XFMR
+BUS
0.20 - 0.90
N/A
Inverter IGBT
−
BUS
HF-XFMR
0.20 - 0.90
N/A
Snubber IGBT
TP2 (D11 Cathode)
HF-XFMR
0.20 - 0.90
N/A
Snubber IGBT
TP2 (D11 Cathode)
TP3 (C2)
0.20 - 0.90
N/A
Inverter IGBT Gate
D2 Cathode
HF-XFMR
N/A
100k
Inverter IGBT Gate
D4 Cathode
−
BUS
N/A
100k
Snubber IGBT Gate
(w/Plug Removed From RC1)
D10 Cathode
TP2 (D11 Cathode)
N/A
100k
Snubber IGBT Gate
(w/Plug Removed From RC1)
D8 Cathode
TP2 (D11 Cathode)
N/A
100k