OM-224 690 Page 24
5-7. Activating The Dry Charge Battery (If Applicable)
!
Always wear a face shield,
rubber gloves and protective
clothing when working on a
battery.
Remove battery from unit.
1
Vent Caps
2
Sulfuric Acid Electrolyte
(1.265 Specific Gravity)
3
Well
Fill each cell with electrolyte to
bottom
of well (maximum).
!
Do not overfill battery cells.
Wait ten minutes and check electro-
lyte level. If necessary, add electro-
lyte to raise to proper level. Reins-
tall vent caps.
4
Battery Charger
!
Read and follow all instruc-
tions supplied with battery
charger.
5
5 Amperes For 30 Minutes
Charge Time
6
30 Amperes For 12 Minutes
Charge Time
Charge battery. Disconnect charg-
ing cables and install battery.
When electrolyte is low, add
only distilled water to cells to
maintain proper level.
1
Tools Needed:
2
4
+
−
3
drybatt1 2008
−
01
−
S-0886
5
6
30 A
5 A
5-8. Connecting The Battery
1/2 in
−
+
Tools Needed:
Conn_batt1 2008
−
02 802 168-E / Ref. 202 705 / 802 313 / S-0756-C
!
Connect negative (
−
) battery
cable last.
Reinstall cover after connecting
battery.
Summary of Contents for D502DX 5+4
Page 2: ......
Page 35: ...OM 224 690 Page 31 6 5 Fuel Hour Gauge Descriptions...
Page 49: ...OM 224 690 Page 45 237 428 A...
Page 72: ...OM 224 690 Page 68 Notes...
Page 73: ...OM 224 690 Page 69 Notes...
Page 74: ...OM 224 690 Page 70 Notes...