Red Arrow Trading
Elsworth House, Herries Road South, Sheffield, S6 1QS
T:
0800 195 0006
F:
0870 043 3946
E:
www.redarrowtrading.com
•
The distances quoted are approximate and
may vary depending on surroundings.
•
Avoid direct sunlight entering the sensor.
•
Do not site within 1m of forced air heating
or ventilation.
•
Do not fix to a vibrating surface.
•
Avoid metallic objects directly in front of
the sensor head.
•
These sensor kits are capable of switching /
controlling more than one luminaire in a
‘master and slave’ set up. This is done by
linking non-sensored fittings (slaves) to the
one with the sensor fitted (master) using the
live output from the sensor.
NOTE!
DO NOT link other fittings containing
microwave sensors together in this way, as it
can cause false triggering of the sensors.
For models: POL14LEDMS
14W LED Slimline
POLO Bulkhead with
Microwave Sensor
Installation
Instructions p.2
DISTANCE TIME LUX
MAX MIN
MAX MIN
MAX MIN
• • • •
• •
Settings
•
The following adjustments can be made using the three dials located on the
sensor unit. DISTANCE, TIME and LUX are adjustable via three rotatable dials.
1.
DISTANCE
Rotate the dial to control the diameter of the detection pattern, from 1m
minimum (fully anti-clockwise) to 10m maximum (fully clockwise). The LED
setting indicator will flash to indicate the setting selected, e.g. 10 flashes = 10m
diameter.
2.
TIME
Rotate the dial to control the length of time the luminaire will stay on after
occupancy has ceased. From 10 seconds minimum (fully anti-clockwise) to
30 minutes maximum (fully clockwise).