Recsea CWS-RX100III User Manual Download Page 8

2. Manipulate   all   buttons   and   dials   several   times   to   flush   out   salt   deposits   and   other 

contaminants.

3. Wipe any water off housing with a soft dry cloth.

4. Open Back Cover.

5. Using the O-ring Removal Pick, remove O-rings.

6. Clean O-ring grooves and contact surfaces using a clean cotton swab. DO NOT clean 

housing, Back Cover or Lens Port with volatile organic solvents or chemical cleaning 

agents such as thinner, gasoline, and benzine, etc.

7. Perform O-RING GREASING & MAINTENANCE as instructed below before re-installing. 

O-RING GREASING & MAINTENANCE ( 1)

CAUTION!

 DO NOT use silicone grease other than that provided by Seatool/Recsea.

1. Using the O-ring Removal Pick, remove O-rings.

2. Clean sand, salt, other contaminants and old grease from O-rings.

3. Clean O-ring grooves and O-ring Contact Surfaces using a clean cotton swab.

4. Visually and  physically check O-rings  by running  them  through  finger  tips, feeling  for 

cuts, cracks  or  any  other  defects  that  may cause  leakage. Such  defects  will  cause  

water leakage, so be sure to replace the O-rings. Be careful not to stretch or pull the O-

rings too much.

5. Squeeze a rice grain sized bead of silicone grease on your thumb and forefinger. Taking 

care not to pull or stretch the O-ring too much, uniformly spread grease on O-ring. Too 

little grease may cause the O-ring to twist in the groove, possibly causing water leakage.

6. Place O-ring in the appropriate O-ring groove, making sure that it is uniform, not twisted 

or bulging out, possibly causing water leakage. When closing back cover, visually check 

O-ring surface, tracing a finger over the to making sure no hair, lint or other contaminants 

are attached.

IMPORTANT NOTES:

 

When housing is not used for long periods, remove O-rings and place in a plastic bag to 

keep them free of dust and other contaminants and store in a place out of direct sunlight. 

Please also be careful of prolonged exposure to direct sunlight during use. The O-rings 

and housing may become deformed, causing water leakage.

After extended periods of non-use, soak closed empty housing in lukewarm for half a day. 

Manipulate all buttons and dials several times. Using a soft, dry cloth wipe away water.

CAUTION!

 

O-rings are an essential part of waterproofing for this housing. Not properly greasing the 

O-rings as directed may cause the O-rings to twist in the O-ring grooves, possibly causing  

water leakage.

 

Always perform the above O-ring, O-ring groove and O-ring Contact Surface maintenance 

and greasing every time you open/close the housing.

 

Please pay close attention and make sure the O-rings are not twisted or bulging, free of  

any contaminants (dirt, hair, etc.), and that foreign objects do not obstruct proper closing 

of the housing Back Cover.

 

DO NOT clean the housing with volatile organic solvents or chemical cleaning agents such 

as thinner, gasoline, and benzine, etc.

 

Housing Back Cover is manufactured using hard coat acrylic. When cleaning use a clean 

soft cloth taking care not to scratch it.

6.

Summary of Contents for CWS-RX100III

Page 1: ...SONY CYBER SHOT DSC RX100 IV Waterproof Housing Recsea CWS RX100IV MANUAL Please read this manual before use NTF CORPORATION UH Division http www seatool net...

Page 2: ...ot store the housing in areas of high humidity high or low temperatures or areas of extreme temperature fluctuation Doing so may cause deterioration of parts When diving use a method of water entry th...

Page 3: ...e Connection Diffuser Mount Fiber Optic SEA SEA and Screw Wrist Strap Reserve O ring Set O ring Removal Pick O ring Grease GETTING TO KNOW YOUR CWS RX100IV HOUSING Please refer to camera manual for ex...

Page 4: ...roduct Number CWS RX100IV Dealer Name Serial Number Dealer Stamp your company name and contact information purchase date model and serial number Recsea Seatool Manufacturing Sales NTF CORPORATION UH D...

Page 5: ...nd press firmly Note Dial will turn to the left counterclockwise While pressing the Open Close Lock Button Using the Open Close Dial Lever turn the dial completely to the left making sure the Open Clo...

Page 6: ...using Mode Dial and rear Push Button function as follow 1 Using the Mode Dial select S Shutter Priority 2 Press Set Button While in S mode the camera s Control Ring is automatically dedicated to Shutt...

Page 7: ...e use of non genuine options are NOT covered under warranty The Accessory Shoe on top of the housing can be used for installation of a target light Please be mindful of the weight of the light s you i...

Page 8: ...he appropriate O ring groove making sure that it is uniform not twisted or bulging out possibly causing water leakage When closing back cover visually check O ring surface tracing a finger over the to...

Page 9: ...wish to purchase Airlock Vacuum System RAVS RX100IV M67 ST Adapter ST NV M67 M67 28LD Adapter AD M67 28LD Close Up 50mm Lens SAL 01 M67 and SAL 01 M52 Close Up Lens 50mm x2 SAL 02 M67DN Bayonet Type w...

Page 10: ...or dissembled by person or company other than Seatoll Recsea 2 If damaged in fire natural disaster such as earthquake flood lightning etc 3 Damage caused by dropping impact vibration 4 When returned...

Page 11: ...MEMO...

Reviews: