Page 1: ...Installation instructions RECOUP Tray DSS S2 1200mm Shower Waste Water Heat Recover unit These instructions are to be left with the user for the homes user pack...

Page 2: ...cy c Pressure Drop d Dimensions Connections 3 Pre installation requirements 6 7 a Basic Principle b Installation configurations c Locating the WWHRU d Design Installation Checklist 4 Installation 8 9...

Page 3: ...er and it is very important to follow all the instructions for installation of the RECOUP Tray DSS S2 1200mm for the product to perform successfully IMPORTANT For recognition of the RECOUP Tray DSS S2...

Page 4: ...r Max Waste water working temp 85 C Mains water connection 1 2 Inch Waste water connection 40 mm Weight of Exchanger 2 7 kg Water volume mains water 0 67 Litres 2 b Performance Efficiency Shower Flow...

Page 5: ...Page 5 V1 02 2 d Dimensions connections RECOUP Tray DSS S2 1200mm 1 Waste Water Connection 2 Cold Water In 3 Pre heated water Out Fig 1 Dimensions Connections 144...

Page 6: ...face Unit HIU on a district heating scheme Mains pressure DHW delivery Note The DHW heater must be a mains pressure system and able to accept preheated cold water 3 b Installation configuration The in...

Page 7: ...of the building The shower must be fitted with a Thermostatic Mixing Valve Keep the distance from the shower waste outlet to the WWHRS to within 3m to maintain a high level of efficiency With the Rec...

Page 8: ...ackaging Box Part No Qty Name 1 1 1 RECOUP Tray DSS S2 1200mm WWHRS unit 900 x 1200 mm 1 2 1 50mm reducer to 40mm Solvent 1 3 1 Installation instructions 1 4 1 NCM SAP Identifier label for nearby boil...

Page 9: ...eturn valve with full flow shut off valve Not supplied should be installed on the mains water supply prior to the WWHR unit in an accessible location It is also recommended that an additional full flo...

Page 10: ...clean lift the lid and clean with soup and warm Once cleaned replace the lid and rinse through with warm water from the shower 6 Warranty The Recoup Tray DSS S2 1200mm comes with a 2 year warranty whi...

Page 11: ...Company contact details Please post completed documents to Recoup Energy Solutions Ltd Telephone 01379 844010 PO Box 365 Email info recoupenergysolutions co uk EYE Website www recoupenergysolutions c...