5
Commissioning
26 / 30
BAL_SD_R62_EN_2V3_BLA_121-006454377
DIAGNOSTICS
FACTORY
SETTINGS
DESCRIPTION
→
INPUTS 0..15
→ DoorSecClosed
OFF
(read only)
Secure door closed
→ DoorSecOpen
OFF
(read only)
Secure door open
→DoorSecLocked
OFF
(read only)
Secure door locked
→ DoorPubClosed
OFF
(read only)
Public door closed
→ DoorPubOpen
OFF
(read only)
Public door open
→ DoorPubLocked
OFF
(read only)
Public door locked
→DCPowerOK
OFF
(read only)
Monitoring power supply (DC power ok)
→ EmergClosing
OFF
(read only)
Contact emergency closing
→ TotalOpening
OFF
(read only)
Contact total opening
→ PanicButton
OFF
(read only)
Contact panic button
→ AlarmStgSec
OFF
(read only)
Alarm door drive secure side
→ AlarmStgPub
OFF
(read only)
Alarm door drive public side
→ AUX01_IN
OFF
(read only)
Programmable input AUX01_IN
→ AUX02_IN
OFF
(read only)
Programmable input AUX02_IN
→ AUX11_IN
OFF
(read only)
Programmable input AUX11_IN
→ AUX21_IN
OFF
(read only)
Programmable input AUX21_IN
→
INPUTS 16..31
→ BdeS1
OFF
(read only)
BDE-S contact 1
→ BdeS2
OFF
(read only)
BDE-S contact 2
→ BdeS3
OFF
(read only)
BDE-S contact 3
→ AUX12_IN
OFF
(read only)
Programmable input AUX12_IN
→ SwDoorPubOut
OFF
(read only)
Contact public door outside (push button,
code card reader etc.)
→ SwDoorPubIn
OFF
(read only)
Contact public door inside (push button, code
card reader etc.)
→ SwDoorSecOut
OFF
(read only)
Contact secure door outside (push button,
code card reader etc.)
→ SwDoorSecIn
OFF
(read only)
Contact secure door inside (push button,
code card reader etc.)
→ SuperUserSec
OFF
(read only)
Contact for temporary deactivation of the
sensor (contact mat, tailgaiting etc.) to pass through
from the secure side to the public side
→ SuperUserPub
OFF
(read only)
Contact for temporary deactivation of the
sensor (contact mat, tailgaiting etc.) to pass through
from the public side to the secure side
→ SensorC1
OFF
(read only)
Contact status sensor "room empty"
→ SensorC2
OFF
(read only)
Contact status sensor "decision YES“
→ SensorC3
OFF
(read only)
Contact status sensor "decision NO"
→ SwTraps
OFF
(read only)
Service flap is open
→ Voice1Busy
OFF
(read only)
Output of the voice card when busy
→ AUX22_IN
OFF
(read only)
Programmable input AUX22_IN
→
OUTPUTS 32..47