Operation
4
BAL_FF_TWIN_EN_2V3_REC_121-006454269
25 / 38
– The flow drops below the fixed threshold value the FlipFlow switches back to INTERLOCK mode and operates
as described above.
NOTICE
Configurable with the service display:
a) Flow and Interlock mode parameters.
b) Flow - > Interlock threshold value.
c) Interlock - > Flow threshold value.
4.2.7
CLEANING mode
This mode allows the FlipFlow to be cleaned without triggering an alarm while keeping the entrance
door closed and locked. This mode can activated by pressing a switch on the FlipFlow. This switch is
provided by the customer.
FlipFlow status when cleaning air side
– Lighting on.
– LED strips off.
– Pictogram at entrance red.
– Pictogram at exit red.
– Entrance door open.
– Exit door closed and locked.
FlipFlow status when cleaning land side
– Lighting on.
– LED strips off.
– Pictogram at entrance red.
– Pictogram at exit red.
– Entrance door closed and locked.
– Exit door open.
– The service display must not be used during monit-
oring
NOTICE
Configurable with the service display:
a) Setting the cleaning time duration
b) Setting the warning time duration