4
Operation
18 / 38
BAL_FF_TWIN_EN_2V3_REC_121-006454269
4
Operation
4.1
How to operate the BDE-S control panel
The half cylinder corresponds to European standard.
The BDE-S is a key switch with 5 positions: Simply insert
the key into the lock and then turn it until the LED cor-
responding to the desired operating mode lights up.
Each time the key is turned, another LED lights up.
4.2
Operating modes and functions
4.2.1
Function LOCK INSTALLATION (optional)
This function allows you to lock the passage of the FlipFlow. The door system can be locked by an
authorized person, which using a key switch.
FlipFlow status
– Lighting off
– LED strips off.
– Pictogram red.
– Doors closed and locked.
The service display must not be used during monitoring
Exiting the function LOCK INSTALLATION
This function can be quitted in two ways:
– The authorized person cancels the function LOCK INSTALLATION by actuating the key switch
again. The FlipFlow switches back to the operating mode set on the BDE-S.
– Switching the BDE-S to CLOSED / LOCKED will unlock the FlipFlow. After that, another mode
can be selected.