RM-216 CB.10 Easy Line Documentation
RDN 10000088
9
07.07.2016
5.3 Parameter list
Pa
ra
m
. no.
Text on the display Explanation
Factory settings Setting range
P01
P01 Pulse time
Pulse time
60 ms
15 ... 2500 ms
P02
P02 Interval
Pause time
10 s
1 ... 500 s
P03
P03 DT interval
Down time interval time
6 s
1 ...100 s
P04
P04 tot Valve no
Total no. of valves*
0
0 ... 128
P05
P05 DT cycles
Down time cleaning cycles
6
0, 2 ... 32
P06
P06 Operating h
Operating hours
–
0 ... 250000 h
P07
P07 Language
Language for the display text
D
D, GB, F, I, NL,
DK, FIN, PL, E
P08
P08 Test Mode
0 = Test mode off
1 = Valve test
2 = Input test
3-5 = For manufacturer
purposes only
Off (0)
0 ... 5
P09
P09 Ser.run hour
Service operating hours
–
–
P10
P10 Ser.run h.AL
Service operating hours alarm
0 h**
0 ... 25000 h**
P11
P11 Ser.r.h.Code
Service operating hours code
0
0 ... 250
*
Number of all valves connected to the RM-216 CB and to the expansion modules. The parameter is used by the equipment for
internal monitoring purposes and need only be set, if expansion modules are fitted. If the equipment detects that the total number
of valves set is different from the actual number of valves controlled, an alarm message is issued.
**
If the parameter is set to the value 0 h, the alarm is switched off.
The parameters P09 and P10 are only displayed if the service operating hours code
(parameter P11) has been entered.