background image

 

 

                                                                                                                                           

 

 

                                   

Manual for heat pump hot water system: classic version |34

 

 

 315 L 

STORAGE 

TANK

TS

Heat pump 

unit

Controller

On/Off 

pulse wire 

(RJ 45 
cable)

NTC Temperature 

Sensor cable

TS

S1: Thermistor 

at 65% level

240V 

power 

cables

LED lights

 

Figure 29 

 

Wiring diagram of Reclaim Energy ASHP hot water system

 

5.5.2.1

 

Heat pump 

After  removing  the  right  side  piping  cover  of  heat  pump  unit,  the  heat  pump  power  terminal  will  be 

accessible as shown in Figure 30.  

 

Summary of Contents for EHPE-4540P

Page 1: ...ntended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance ...

Page 2: ...del ID EHPE 4540P Parameter Value Unit Power input 0 916 kW Thermal output 4 7 kW COP 5 24 Refrigerant CO2 R744 Output water temperature 63 C Power supply 240V 50 Hz V Hz Current input Max 10 0 Amps Power input Max 2 3 kW Noise level 37 dB Ambient temperature 10 to 43 C Dimension H W D 675 825 300 mm Weight 48 kg Rain resistance IP 4 Water port connections inlet outlet 1 2 BSP 12 7mm Inch mm ...

Page 3: ... wire RJ 45 cable NTC Temperature Sensor cable TS S1 Thermistor at 65 level 240V power cables LED lights Figure 29 Wiring diagram of Reclaim Energy ASHP hot water system 5 5 2 1 Heat pump After removing the right side piping cover of heat pump unit the heat pump power terminal will be accessible as shown in Figure 30 ...

Page 4: ...at pump terminal to the heat pump GPO The process of connecting power cable to heat pump terminal is shown in figures below Figure 31 How to attach the power cable Heat pump GPO Heat pump terminal Electrical Conduit Heat pump PCB display where RJ45 cable should be connected to Water pipe connections ...

Page 5: ...2 2 Controller There are 3 steps per below 1 Wiring of RJ45 cable from the controller module to heat pump display unit as shown in Figure 33 and Figure 34 2 Plug in the power cable to the controller GPO 3 Placing the sensor cable to the associated sensor location on the tank L Earthing Cable Electric Cable Press Supply Cable N ...

Page 6: ...r system classic version 37 Figure 33 How to connect RJ45 PATCH cable to heat pump display unit Figure 34 Wiring of RJ45 cable from controller to the PCB display unit RJ45 cable connection to the PCB display unit Connect heare RJ45 ...

Page 7: ...igure 6 A photo of supplied controller unit CR2032 Lithium Battery holder for the real time clock battery Boost button Temperature button Menu button RJ45 Patch cable connector 230vAC power terminals Temperature sensor terminals Remote Control input terminals ...

Page 8: ...e the operational mode and revert back after completion One shot boost button Enclosure Dimension mm 130H x 130W x 35D Material Polycarbonate Mounting Screw mountable Connectors RJ45 for Heat Pump Interconnection Fixed screw connect terminals for Power and Temperature Sensors Power Requirements 80 264vAC 47 63Hz Operating Temperature 25 to 75o C Input Requirements Input CON2 Term 1 2 Temperature S...

Page 9: ...ump hot water system classic version 16 230v Australian approved power cable plug pre fitted RJ45 10 meter patch cable pre fitted Temperature Sensor 2 meter lead pre fitted Mounting screws and spacers x 4 CR2032 battery ...

Reviews: