Beijing Reci Laser Technology Co., Ltd
User Guide for Single Module Fiber Laser
38
Chapter 6 Common faults treatment
6.1 Fault alarm and query
In case of fault alarm, the laser will automatically turn off by turning off the
internal power supply. At the same time, the signal of fault will output a conduction
signal with the 9th pin (EX_AL) and the 10th pin (EX_ALARM_OUT-)
in the 16 pin Ctrl_Interface on the rear panel. And then the front panel display will
display the fault information at this time.
The customers can make detailed query on the software fault query page when
they need to know more detailed fault information.
6.2 Common faults solution
The failure instructions and possible solutions are as follows:
:
Table 6.1 the failure instructions and possible solutions
NO
MESSAGE
DESCRIPTION
SOLUTION
1
Emergency
Stop fault
The Emergency Stop is pressed.
Turn the emergency stop clockwise, and
restart the laser to see if the fault still
occurs. If there is still a fault after all of
above treatments, please contact our
after-sales service personnel.
2
QBH fault
Contact between the QBH and
the cutting head is not in place.
Reconnect the QBH and cutting head,
restart the laser to see if the fault still
occurs. If it does, pull out QBH with the
ring contactor short circuit connected,
and then restart the laser source. If there
is still a fault after all of above
treatments, please contact our after-sales
service personnel.