Rebel TOOLS RB-1060 User Manual Download Page 6

6

EN

Disconnect power tool from its power source before maintenance, cleaning or any 

intervention on product; or when you do not use product.

Disconnect battery charger power cord if cord or extension cord is damaged or cut 

during operation. Unplug charger by pulling the plug. Do not pull the cord.

Do not dispose of the product in unsuitable containers.

Separate collection for Li-Ion battery.

The product is in accordance with the applicable safety standards in the 

European directives.
Explosion hazard! Protect battery against heat and fire.

Do not throw the battery into fire. Do not burn.

Do not throw the battery into water.

Maximum ambient temperature: 40°C/45°C.

Always charge the battery in ambient temperature b10°C to +40°C.

General power tool safety warnings

1. Keep work area clean and well lit. 

Cluttered or dark areas invite accidents.

2. Do not operate power tools in explosive atmospheres, such as in the presence of

flammable liquids, gases or dust. 

Power tools create sparks which may ignite the dust

or fumes.

3. Keep children and bystanders away while operating a power tool. 

Distractions can

cause you to lose control.

Never allow children to operate the power tool. 
Children should be supervised to ensure that they do not play with the power tool.

Electrical safety

Before connecting the power tool to power supply socket, make sure the voltage 

indicated on the power tool corresponds to the voltage in the power supply socket.

1. Power tool plugs must match the outlet. Never modify the plug in any way. Do not

use any adapter plugs with earthed (grounded) power tools. 

Unmodified plugs and

matching outlets will reduce risk of electric shock.

2. Avoid body contact with earthed or grounded surfaces, such as pipes, radiators,

ranges and refrigerators.

 There is an increased risk of electric shock if your body is

earthed or grounded.

3. Do not expose power tools to rain or wet conditions.

 Water entering a power tool will

increase the risk of electric shock.

Summary of Contents for RB-1060

Page 1: ...TOOLS CORDLESS AIR PUMP USER MANUAL model RB 1060 EN GR...

Page 2: ......

Page 3: ...ter Tightening nut Nakr tka mocuj ca Piuli de str ngere Arbeitslicht Work light wiat o robocze Lumin de lucru EIN AUS Schalter ON OFF ON OFF switch W cznik Comutator pornire oprire Zubeh rfach Accesso...

Page 4: ...n matice Tuerca de fijaci n R gz t anya Pracovn sv tlo Luz de trabajo Munkaf ny P ep na Interruptor ON OFF Kapcsol gomb lo n prostor pro p slu enstv Caj n para accesorios Tartoz k t rol Rukoje Mango M...

Page 5: ...ual Risk of injury and or damage and or deterioration of product in case of noncompliance to safety requirements Risk of electric shock Variable electronic speed Rotation left right Indoor use only Cl...

Page 6: ...plosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes 3 Keep children and bystanders away while operating a power...

Page 7: ...wer tool may result in personal injury 5 Do not overreach Keep proper footing and balance at all times This enables better control of the power tool in unexpected situations 6 Dress properly Do not we...

Page 8: ...attery tool use and care 1 Do not attempt to open the battery If the battery is damaged in any way stop using it and do not attempt to recharge it Short circuit or electric shock or explosion hazard 2...

Page 9: ...k of electric shock personal injury and damage 6 Never attempt to recharge non rechargeable batteries 7 Only use the charger at ambient temperatures between 10 C and 40 C Store charger in a dry locati...

Page 10: ...erly maintained Injuries and damage to property to due to broken accessories that are suddenly dashed Warning This power tool produces an electromagnetic field during operation This field may under so...

Page 11: ...running but not actually doing the job may significantly reduce the exposure level Identify additional safety measures to protect the operator from the effects of vibration such as maintain the power...

Page 12: ...hose loosen the tightening nut by turning it clockwise Grasp and pull the hose so that it detaches from the chuck Store the hose in the storage area on the top of the power tool Fitting and removing t...

Page 13: ...in two ways Manually by pressing and holding the ON OFF switch until desired pressure is reached then release the ON OFF switch Automatically first set the desired pressure with the buttons Wait until...

Page 14: ...e battery so that it does not move in the package The product and the user manual are subject to change Specifications can be changed without further notice LEARN MORE For more information on this dev...

Page 15: ...ctives Product standard EN 60745 1 2009 A11 2010 EN 60745 2 1 2010 EN 60745 2 2 2010 EK9 BE 77 V3 2015 EK9 BE 87 2014 EK9 BE 88 2014 EK9 BE 89 2014 EK9 BE91 2015 EN 55014 1 2006 A1 2009 A2 2011 EN 550...

Page 16: ...16 GR II...

Page 17: ...17 GR 40 C 45 C 10 C 40 C 1 2 3 1...

Page 18: ...18 GR 2 3 4 5 6 RCD RCD 1 2 3 4 5 6 7...

Page 19: ...19 GR 1 2 3 4 5 6 7 8 8 9 10 11 12...

Page 20: ...20 GR 1 1 2 3 4 5 6 7 8 9 10 OFF 11 10 C 40 C 40 C...

Page 21: ...21 GR 1 2 3 4 5 6 7 10 C 40 C 40 C 8 9 5 5...

Page 22: ...22 GR...

Page 23: ...23 GR 20 V 2 Ah Li Ion RB 2001 1 1 5 AC RB 2001 CH 220 240 V 50 60 Hz 21 V 2 2 A 15 l bar PSI 7 bar 100 PSI 300 mm 1 1 kg LPA 80 8 dB A K 3 dB A LWA 91 8 dB A K 3 dB A 3 240 m s2 K 1 5 m s2 EN 60745...

Page 24: ...24 GR LED LED LED 1 AC LED 1 5 5 4 5...

Page 25: ...25 GR 3 6 ON OFF ON OFF ON OFF ON OFF 7 ON OFF 7 bar PSI...

Page 26: ...26 GR 1 2 3 4 ON OFF ON OFF ON OFF ON OFF 5 H 6 7 0 7 bar 0 C...

Page 27: ...27 GR LECHPOL ELECTRONICS Sp z o o Sp k ul Garwoli ska 1 08 400 Mi tne...

Page 28: ......

Page 29: ...www moutsioulis gr...

Reviews: