RealFlame Riverside C539LP Manual Download Page 11

13.)

 

Lighting

Lighting Instructions

LIGHT

LOW

Control Knob

PUSH

IN

10

1.

 Read and understand all operating instructions before lighting.

 

   

   

2.

 Burner control knob must be in the OFF position.

3.

 Ensure that gas supply is connected and open.

4.

 Push and hold igniter button to create sparks.

 

5.

 While holding the igniter button with one hand, use your other    

    hand to push and turn the control knob to the LIGHT position    

    to ignite the burner. 

6. 

Keep burner control knob pressed in for 15-30 seconds 

    after ignition.

7.

 If ignition does not occur in 30 seconds, turn control knob to 

    the OFF position and turn gas off at the source; wait 5 

    minutes until gas has cleared and repeat lighting procedure.

8.

 After lighting, rotate the burner control knob counter 

    clockwise to LOW setting. Observe flame; to make sure all 

    burner ports are  lit.

9. 

Adjust the flame to the desired height with the     

    control knob. Flames should be between 8-13” in height.

 

1. 

Wearing heat-resistant gloves, position the burning   

    long match or extended lighter near the side of    

    the burner. DO NOT lean over the fire bowl while    

    lighting.

2.

 Turn control knob counterclockwise to LIGHT.

3.

 Remove long match/extended lighter.

4.

 After lighting, rotate the burner control knob counter    

    clockwise to LOW setting. Observe flame; make sure    

    all burner ports are lit. 

5.

 Adjust the flame to the desired height with the 

    control knob. 

6.

 Replace the battery as soon as possible.

When using this method to light your fire bowl use heat-resistant gloves and follow the step- 

by-step instructions. Failure to do so could result in severe injury.    

If burner flame goes out during operation, immediately turn the control knob OFF position and

let the gas clear a minimum of 5 minutes before attempting to re-light the fire bowl.   

   

Using the Igniter

!

!

WARNING

WARNING

If battery is dead you may 

TEMPORARILY use 

  

a long match or extended butane lighter
If doing so:

                        

20.3 - 30.5 cm

8-13”

Summary of Contents for Riverside C539LP

Page 1: ...n operation and maintenance instructions thoroughly before installing or servicing this equipment IMPORTANT WARNING SAVE THESE INSTRUCTIONS DANGER If you smell gas gas to the appliance 2 Extinguish an...

Page 2: ...ire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit Th...

Page 3: ...NATURAL GAS CONVERSION 2 1 Flip bowl upside down Place on a soft surface to avoid damaging the finish 2 Disconnect LP hose from valve...

Page 4: ...NATURAL GAS CONVERSION 3 3 Disconnect bellows Corrugated Stainless Steel Tube CSST from burner base Bellows...

Page 5: ...4 NATURAL GAS CONVERSION 4 Remove the existing LP orifice spud LP Orifice Spud...

Page 6: ...d verify it is the correct number The sign 3 9mm should be on the end of the orifice spud 6 Slip sleeve over primary air opening See fig 1 Next screw the new NG orifice spud into the burner base See f...

Page 7: ...6 NATURAL GAS CONVERSION 7 Re attach bellows CSST to new spud Bellows...

Page 8: ...8 Attach NG hose to the input side of the valve 9 Attach quick disconnect to gas supply NATURAL GAS CONVERSION House Natural Gas Piping Shut off Valve Quick Disconnect Socket NG Gas Hose To Fire Bowl...

Page 9: ...o the National Fuel Gas Code Contact Real Flame for more information at 1 800 654 1704 11 Note to installation technicians Verify the manifold pressure by using a 3 8 flared T junction at the location...

Page 10: ...ure the fire bowl control knob is OFF Then turn the natural gas on at its source Spray leak solution on the valve connections paying particular attention to the areas indicated by the arrows If any bu...

Page 11: ...ired height with the control knob Flames should be between 8 13 in height 1 Wearing heat resistant gloves position the burning long match or extended lighter near the side of the burner DO NOT lean ov...

Page 12: ...avec le kit no par NOTES ______________________________________________________ _____________________________________________________________ _________________________________________________________...

Page 13: ...l installation l op ration et des instructions de maintien fond avant stallation ou entretien de cet quipement IMPORTANT DANGER imm diatement votre fournisseur de gaz ou le service des incendies C S...

Page 14: ...exactement un incendie une explosion ou la production de monoxyde de carbone peut causer des dommages mat riels des blessures corporelles ou la pertes de vie Le service d entretien qualifi est respon...

Page 15: ...CONVERSION DU GAZ NATUREL 2 1 Retournez la bol de feu sur son c t Placez sur une surface souple pour viter d endommager la finition 2 D branchez le tuyau LP de la valve...

Page 16: ...CONVERSION DU GAZ NATUREL 3 3 Soufflets D brancher le soufflet Tubes en acier inoxydable ondul CSST de la base de br leur...

Page 17: ...4 CONVERSION DU GAZ NATUREL 4 Orifice de patate LP...

Page 18: ...3 9 mm devrait tre sur l extr mit d orifice de patate 6 issez le gaine sur l ouverture a rienne princi ir fig Ensuite vissez la nouvelle patate d ifice N ans la base de br leur ir fig Gaine L ouvertu...

Page 19: ...6 CONVERSION DU GAZ NATUREL 7 Rattachez les soufflets CSST la nouvelle patate Soufflets...

Page 20: ...7 8 9 CONVERSION DU GAZ NATUREL Tuyauterie de Gaz naturel de Maison Soupape d arr t Prise de d connexion rapide Tuyau de Gaz NG Au Bol de Feu...

Page 21: ...s installations une altitude sup revendeur local ou fournisseur de gaz avant l installation comme l valuation d entr e devrait tre r duite d enviro pour c dessu nat lu in 11 CONVERSION DU GAZ NATUREL...

Page 22: ...sur le gaz naturel sa source Pulv riser la solution de fuite sur les connexions de valve en accordant une attention particuli re aux endroits indiqu s par les fl ches voir des bulles apr s plusieurs t...

Page 23: ...cm de hauteur 1 En portant des gants r sistant la chaleur placez la longue allumette br lant ou briquet au du br leur Ne penchez pas la bol de feu en allumant 2 Tournez le bouton de commande de tour...

Page 24: ...______________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________...

Page 25: ...IMPORTANTE ADVERTENCIA GUARDE ESTAS INSTRUCCIONES PELIGRO Si siente olor a gas 1 Apague el artefacto 2 Extinguir cualquier llama abierta 3 Si el olor contin a mant ngase alejado del artefacto y llame...

Page 26: ...observa es trictamente puede producirse mon xido de carbono incendio o explosi n causando da os materiales lesiones personales o p rdida de vidas La agencia de servicio calificada es responsable de la...

Page 27: ...CONVERSI N DE GAS NATURAL 2 1 Gire la taz n de fuego sobre su lado Coloque sobre una superficie suave para evitar da ar el acabado 2 Desconecte la manguera de LP de la v lvula...

Page 28: ...CONVERSI N DE GAS NATURAL 3 3 Desconecte el fuelle Tubos de acero inoxidable corrugado CSST de la base del quemador Fuelle...

Page 29: ...4 CONVERSI N DE GAS NATURAL 4 Retire el intermediario de LP existente Intermediario de LP...

Page 30: ...ea el n mero correcto El n mero 3 9mm debe estar en el extremo del intermediario 6 Deslice la manga sobre la abertura de aire primario Ver fig 1 Luego atornille el nuevo intermediario de GN en la base...

Page 31: ...6 CONVERSI N DE GAS NATURAL 7 Vuelva a conectar el fuelle CSST al nuevo intermediario Fuelle...

Page 32: ...de GN a la entrada de la v lvula 9 Conecte la desconexi n r pida al suministro de gas CONVERSI N DE GAS NATURAL Tubo de gas natural V lvula de cierre Conexi n de la desconexi n r pida Manguera de gas...

Page 33: ...el del mar Consulte el C digo Nacional de Gas Combustible Contacte a Real Flame para obtener m s informaci n al 1 800 654 1704 11 Nota para los t cnicos de instalaci n Verifique la presi n del colecto...

Page 34: ...nistro de gas natural Roc e la soluci n de fugas en las conexiones de la v lvula prestando especial atenci n a las reas indicadas por las flechas Si aparecen burbujas cierre el suministro de gas vuelv...

Page 35: ...0 3 30 5 cm de altura te la llama a la intensidad deseada mediante la perilla de control 1 Usando guantes resistentes al calor coloque el f sforo largo encendido o encendedor de gas butano encendido p...

Page 36: ..._______________________________________ _____________________________________________________________ _____________________________________________________________ ____________________________________...

Reviews: