background image

 

7

 CAUTION: 

Ensure  installation 

does  not  allow  replace  to  be  in 

direct  contact  with  building  vapor 

barrier or insulation and meets all 

local building code.

!

NOTE: 

A  dedicated,  properly 

fused 13 Amp circuit is required, 

rated for the appropriate voltage 

(230-240V).

 WARNING: 

Construction 

and  wiring  must  comply  with 

local building codes and other 

applicable regulations to reduce 

the  risk  of  re,  electric  shock 

and injury to persons.

 WARNING: 

To reduce the risk 

of  re, electric shock or injury to 

persons, always use a licensed 

electrician.

 WARNING: 

To reduce the risk of 

re, do not store or use gasoline or 

other  ammable vapors or liquids in 

the vicinity of the heater.
1.  Select  a  location  that  is  not 

susceptible  to  moisture  and  is 

away from drapes, furniture and 

high traf c.

2. 

Unpack  the 

replace  and 

hardware from the box.

!

NOTE: 

Leave  the  front  glass 

and  partially  re ective  glass, 

safely, in the box until the time you 

 Fireplace Installation 

are ready to install it.
3. 

Store  the  replace  in  a  safe, 

dry and dust free location until 

you  are  ready  to  install  the 

replace.

Installation

 

CAUTION:

 Two people will be 

required  for  various  steps  of 

this procedure.

This design of this unit allows three 

options  for  installation: 

partial 

recess

ush  mounted

  or 

sub-

surface

 mounted. 

 

CAUTION: 

Sub-surface

 

mounting should be limited to 

½

 

in. (12 mm) to ensure adequate 

air  ow of heated air out of the 

rebox area.

1.  Prepare  a  wall  with  a  framed 

opening  of  16  in.  (40.6  cm) 

high, 

•  XLF50 - 50 ⅝ in. (128.7 cm)
•  XLF74 - 74 ⅝ in. (189.7 cm)
•  XLF100  -  100  ⅝  in.  (255.7 

cm)  wide,  with  a  bottom  sill 

that  is  a 

minimum

  of  4  in. 

(10.2  cm)  deep.  The  sill  can 

be  constructed  to  support  the 

front  of  the  unit  to  allow  the 

power  supply  wires  to  easily 

be run behind or  ush with the 

back of the unit and a pass thru 

10

NOTE: A 10 Amp, 230 – 240 Volt circuit is required.

A dedicated circuit is preferred but not essential in

all cases. A dedicated circuit will be required if, after

installation, the circuit breaker trips or fuse blows on

a regular basis when the heater is operating.

Summary of Contents for Ignite RF XLF100

Page 1: ...00 08 53411 0 Issue 1 The product complies with the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the e...

Page 2: ...asize CAUTION Procedures and tech niques which if not carefully followed will result in damage to the equip ment WARNING Procedures and techniques which if not carefully followed will expose the user...

Page 3: ...product it is important to be able to locate it in the event of requiring technical support Model and Serial Number Label Please carefully read and save these instructions CAUTION Read all instructio...

Page 4: ...Do not place material or garments on the appliance or obstruct the air circulation around the appliance for instance by curtains or furniture as this could cause overheating and a re risk In the even...

Page 5: ...perform user maintaince The appliance must be positioned so that the plug is accessible If the supply cord is damaged it must be replaced by the manufacturer or service agent or similarly quali ed pe...

Page 6: ...regarding the operation of your electric replace or require service contact the relavent customer service as listed on your warrenty card 3 For dimensions of your replace refer to Figure 1 16 49 in 41...

Page 7: ...me you Fireplace Installation are ready to install it 3 Store the replace in a safe dry and dust free location until you are ready to install the replace Installation CAUTION Two people will be requir...

Page 8: ...The unit is provided with an installed in 2 0 cm trim Depending on the installation this trim can be removed by removing the securing screws and the 4 trim pieces 3 Lift replace from the bottom and t...

Page 9: ...cavity of the unit only for XLF74 and XLF100 units 3 Before installation ensure that the front glass and the partially re ective glass are clean Particles can be removed by dusting lightly with a clea...

Page 10: ...evenly distribute the smaller media into the Media Tray 7 Carefully place the front glass into the lip located at the bottom of the opening of the firebox 8 Tip the front glass into the unit and secu...

Page 11: ...l Operation WARNING This electric firebox must be properly installed before it is used This firebox operates with Comfort averTM technology which automatically adjusts the fan speed and heater wattage...

Page 12: ...unit can be operated in Heat Only Mode When the unit is only running with the heater the icon will continuously be displayed on the Display NOTE The heater may emit a slight harmless odor when rst use...

Page 13: ...combinations are available in the unit Changed by repeatedly pressing the corresponding button on the remote or the unit Adjusted by repeatedly pressing the corresponding button on the remote Indicat...

Page 14: ...he main disconnect panel and call technical support Cycles through the different preset light settings of the unit this includes different combinations of colors of the ame base and media lighting NOT...

Page 15: ...ated with an accumulation of dust or dirt on or in the unit as this can cause a build up of heat and eventual damage For this reason the heater must be inspected regularly depending upon conditions an...

Page 16: ...ct to availability provided it has been installed and operated in accordance with these instructions Your rights under this guarantee are additional to your statutory rights which in turn are not affe...