![Real Flame Hot Box Installation & Operating Manual Download Page 27](http://html1.mh-extra.com/html/real-flame/hot-box/hot-box_installation-and-operating-manual_1425133027.webp)
TROUBLE SHOOTING FOR ELECTRONIC IGNITION AND
POWER FLUE SYSTEM.
(continued)
The power flue and electronic control box have a red LED light that indicates the
possible cause of a problem, the LED light will flash in different sequences for
different problems, the most common are:-
Long Flash
Short Flash
1
0
Normal Running State.
1
1
Flame Failure.
1
2
Waiting for pressure switch ON
1
3
Waiting for pressure switch OFF
2
1
Maximum retries exceeded