WARNING

The “Captiva 600 & 900” have a primary safety glass fitted in front of the glass door. This safety glass is
fitted to these appliances to reduce the risk of injury from burns and at no time should this glass be
permanently removed.

For protection of young children or the infirm, a secondary guard is required.

WARRANTY

Provided your Real Flame gas fire is installed in strict accordance with our installation instructions, the
firebox is unconditionally guaranteed for ten years and all other parts for twelve months from date of
purchase.

This unconditional warranty covers parts and labour at our discretion taking into consideration normal wear
and tear and does not cover fires installed in outdoor settings.

INSTALLATION NOTICE

The installation of this appliance is only to be carried out by an authorised person in accordance
with the Manufacturer’s Instructions, local gas fitting regulations, AG601 installation code for gas
burning appliances and any other relevant statutory regulations. 

In all cases the installation of this appliance shall meet the requirements as set out in
AS5601/AG601.

NOTE: A slight smell may be apparent for the first few hours of use. This is due to the heat resistant
paint curing. It is recommended to open windows in the room for the first lighting of the fire. In some
instances a slight discolouration may occur inside the firebox.  This is a normal condition and is not
covered by warranty.

IMPORTANT SAFETY NOTICE

DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE.

DO NOT USE OR STORE FLAMMABLE MATERIAL NEAR THE APPLIANCE.

DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILST IT IS IN OPERATION.

CARE MUST BE TAKEN TO ENSURE THAT ANY RETURN AIR REGISTER OR EXHAUST SYSTEM
DOES NOT ADVERSLEY AFFECT THE OPERATION OF THE APPLIANCE OR DRAUGHT OF
CHIMNEY OR FLUE.

WARNING

The outer glass panel gets extremely hot! Precaution should be taken and young children
supervised at all times when heater is operating.

Summary of Contents for CAPTIVA

Page 1: ...UE SPACE HEATER INSTALLATION OPERATING MANUAL The Captiva 600 900 are approved to be installed as a zero clearance firebox and are designed to operate on Natural Gas and Propane LPG gases ONLY Approva...

Page 2: ...al gas fitting regulations AG601 installation code for gas burning appliances and any other relevant statutory regulations In all cases the installation of this appliance shall meet the requirements a...

Page 3: ...8 Vertical venting installation 10 Tests to be carried out by installer 11 Servicing and maintenance 11 Parts list 13 Gas control assembly 13 Flue termination cowls regulations 15 Remote control opera...

Page 4: ...Point Low Injector Size Gas Consumption 1 00 mm 15 Mj hr MODEL CAPTIVA 900 SERIAL NO DATE OF MANUFACTURE GAS TYPE APPROVAL GSCS20081 NATURAL GAS 1 00 kPa Test Pressure Point High Injector Size Gas Co...

Page 5: ...rature which could cause burns of clothing ignition Young children should be carefully supervised when they are in the same room as the appliance Clothing or other flammable materials should not be pl...

Page 6: ...6 B C D E F G H I J K L FRONT 4 SIDED FRONT 3 SIDED B A C DIMENSIONS Captiva 600 A B C D E F G H 782 780 588 655 860 645 190 180 I J K L 385 140 85 120 Captiva 600 Trim A B C 790 930 840...

Page 7: ...I J G H F C D B K L M E FRONT 4 SIDED FRONT 3 SIDED B A C DIMENSIONS Captiva 900 Captiva 900 Trim A B C 790 930 840 A B C D E F G H 790 780 860 923 840 600 255 180 I J K L M 410 180 85 100 120 7...

Page 8: ...380 775 865 790 655 930 100 60 120 85 900 785 860 410 750 835 1020 920 930 100 90 120 60 Flue Size Inner Outer 600 100mm 180mm 900 100mm 180mm Overall Dimensions in mm A Flange Bottom of 3 sided trim...

Page 9: ...d D dimensions as shown with framework included below fire to required height Ensure frame is suitable for fire weight Plasterboard to run beyond stud as shown and to go behind fixing flange on unit M...

Page 10: ...nced Flue termination will be located Flue terminations shall not be recessed in walls or sidings EXTREMELY IMPORTANT In heavy snow areas take extra care to prevent blocking flue termination with snow...

Page 11: ...ING AND MAINTENANCE To follow when servicing removing fan or changing valve or control modules IMPORTANT POWER MUST BE ISOLATED PRIOR TO CARRYING OUT THE SERVICE MAINENANCE SERVICE MAINENANCE ONLY TO...

Page 12: ...cover from front of burner and then gently remove burner taking care not to move the sparker sensor Figure 9 Remove front protection mesh by removing screws Figure 11 To remove control module firstly...

Page 13: ...the fan out the remote box must be removed and the burner tube is to be undone at the bulkhead Figure 14 Remove the burner to be nut either from the bulkhead or the brass elbow the valve can then be r...

Page 14: ...ASSEMBLY Inlet Test Pressure Point Outet Test Pressure Point Adjustment for High Adjustment for Low Gas Outlet Gas Inlet Gas Control Valve Module Box Remote Control Module Sparkers Sensor PARTS LIST...

Page 15: ...15 CAPTIVA FLUE TERMINATION COWLS REGULATIONS Balanced Flue...

Page 16: ...he high setting The fan will automatically come on in the high mode after the fire has been operating for 3 minutes 20 seconds When the fire shuts off on auto mode or is shut off in manual mode the fa...

Page 17: ...have the remote near the unit to ensure the remote can communicate with the control Located in the bottom of the heater The Captiva will operate through the remote either in Manual Mode or Auto Mode...

Page 18: ...he flame will be extinguished The fan will run for further 3 minutes on High before shutting down If the room temperature then drops down to 25 or lower the flame will again be lit and the fan will be...

Page 19: ...k like the diagram below once it has been installed and before mantelpiece has been attached 3 Refit trim over the marble Firebox A B C E D 200mm 200mm F 19 X X X X X X X X X X X X Polished Only for b...

Page 20: ...1840 1240 1140 900 60 80 240 600 BOX 1695 1240 750 820 20 320 430 900 BOX 1840 1240 980 820 20 320 430 MANTELPIECE DIMENSIONS Captiva Flush Captiva Boxed D B G C A E 200 x 200mm marble block Marble h...

Page 21: ...trol CON9 CON12 12 11 10 9 8 7 6 5 4 3 2 1 1 9 8 7 6 5 4 3 2 1 2 CON2 Reset Button Fuse 1 MO MO Ignitor High Speed Medium Speed Low Speed Neutral Neutral Neutral Active Low Med High TH1 TH2 MOD1 MOD2...

Page 22: ...22...

Page 23: ...23...

Page 24: ...howroom 654 Pacific Highway Chatswood NSW 2067 Ph 02 8905 0189 Fax 02 8905 0192 E mail info realflame com au Miranda NSW Showroom 36 Kareena Rd Miranda NSW 2228 Ph 02 8513 6202 Fax 02 9520 1974 E mail...

Reviews: