background image

GAS CONTROL ASSEMBLY

Inlet Test

Pressure Point

Outet Test

Pressure Point

Adjustment 

for High

Adjustment 

for Low

Gas Outlet

Gas Inlet

Gas Control Valve

Module Box

Remote Control Module

Sensor

PARTS LIST

Remote Control 

18

Summary of Contents for Captiva Island 2 sided

Page 1: ...PACE HEATER INSTALLATION OPERATING MANUAL The Captiva Island gas fire is approved to be installed as a zero clearance firebox and are designed to operate on Natural Gas and Propane LPG gases ONLY Approval Number GMK10060 VERSION 14 ...

Page 2: ...een installed in an outdoor setting 4 Limit of Liability The warranty provided under this warranty is limited to replacement or repair of the Real Flame Gas Burner only at our option To the extent permitted by law Real Flame excludes liability for consequential loss or any other loss or damage caused to property or persons arising from any cause whatsoever and damage arising from normal wear and t...

Page 3: ...601 2013 NOTE Not intended for fireplace insert Do not install in a fireplace NOTE A slight smell may be apparent for the first few hours of use This is due to the heat resistant paint curing It is recommended to open windows in the room for the first lighting of the fire In some instances a slight discolouration may occur inside the firebox This is a normal condition and is not covered by warrant...

Page 4: ...Dimensions 3 sided 8 Timber frame installation 9 Fluing options 11 Ceramic set up and installation procedures 12 Servicing and maintenance 14 Parts list 18 Flue termination cowls regulations 19 Remote control operating guide 20 Electrical diagram 23 Real Flame contact information 24 4 ...

Page 5: ...43 Mj hr LPG 2 65 kPa Test Pressure Point High Injector Size Gas Consumption 2 x 1 30 mm 43 Mj hr NATURAL GAS 0 50 kPa Test Pressure Point Low Injector Size Gas Consumption 2 x 2 55 mm 33 Mj hr LPG 1 50 kPa Test Pressure Point Low Injector Size Gas Consumption 2 x 1 30 mm 33 Mj hr DATA PLATE Affixed to the base of the unit for reference to gas pressure consumption 5 ...

Page 6: ... flammable materials should not be placed on or near the appliance SELECTING YOUR APPLIANCE LOCATION Your appliance may be installed in any location that is free of ducted return air vents or electrical wiring and plumbing Safety as well as efficiency of operation must be considered when selecting the heater location Try to select a location that does not interfere with room traffic and offers acc...

Page 7: ...7 DIMENSIONS Captiva Island 2 sided trim B C D E F G H I J B C A B C 890 995 50 A B C D E F G H 870 560 1100 940 160 100 180 100 I J 245 115 Captiva Island 2 sided ...

Page 8: ...B C D E F G H I J B C D SIDE x 2 END DIMENSIONS Captiva Island 3 sided trim A B C D 890 995 50 575 A B C D E F G H 870 560 1100 940 160 100 180 100 I J 245 115 8 Captiva Island 3 sided ...

Page 9: ...arance casing The flue can terminate horizontally or vertically Vertical top termination Horizontal rear termination A B C D E F G H 890 1100 560 715 805 210 470 210 Model 2 sided 890 1100 560 715 805 210 470 210 3 sided Dimensions in mm A B C D E H G 120 200 65 120 Gas Inlet On base Power Cord On base The fan control module and remote control module are all located behind the louvre F Gas connect...

Page 10: ...ANT Install unit and fluing before plasterboard NOTE Plaster to run beyond stud and behind trim A Plaster NOTE Plasterboard to run beyond stud as shown and to go behind trim Note The C dimension is the finished depth including cladding Note The D dimension is the minimum required to allow room for the flue to exit the unit and fit a 90 elbow for vertical termination FIRE FIRE FIRE Clearances from ...

Page 11: ...walls or sidings EXTREMELY IMPORTANT In heavy snow areas take extra care to prevent blocking flue termination with snow removal equipment Flue gases exiting flue terminals are very hot and must not be restricted to assure fireplace combustion is not affected Do not place build any obstruction plant any bushes or for any reason attempt to conceal the flue termination To do so will affect the operat...

Page 12: ...1 Remove logs and coals from box and place supplied coals randomly around burner as shown Do not cover burner rail Figure 3 Place logs A B as shown in mirror image of logs A B on opposite side Figure 2 Install logs A B as shown Figure 4 Place logs C D as shown again logs C D will be a mirror image NOTE There should be the following ceramics in the box 2 x large side logs 2 x medium side logs 2 x c...

Page 13: ...o the burner as shown Figure 3 Finally place the 32 small pebbles as shown Figure 2 Add the 16 medium pebbles as shown NOTE There should be 32 small pebbles 16 medium pebbles and 12 large pebbles contained in the box PEBBLE OPTION To install pebbles follow the instructions below taking care not to place the pebbles over the burner rail 13 ...

Page 14: ...UALIFIED TRADESMAN SERVICE MAINTENANCE ONLY TO BE CARRIED OUT BY AN AUTHORISED PERSON Figure 1 To remove glass panel or panels first remove the top louvre frames by removing the Allen screws Figure 3 Once the louvres are loose you can remove the frames and then take the louvre sets off Figure 5 Remove the outer glass Figure 2 Then loosen the louvres by loosening the screws at each end Figure 4 Now...

Page 15: ...screws from top and two from bottom Figure 8 Slide the inner glass out of the side and also the end if 3 sided model supplied Figure 9 Set up ceramics as per page 12 and 13 Figure 11 To remove the control module disconnect wires and lift from double sided tape Then remove module Figure 10 To remove the remote control module remove all wire connections and lift from double sided tape Then remove mo...

Page 16: ...o remove the fan undo the two screws from the bracket in front of the fan and remove bracket Figure 16 Remove the bottom curb and slide the fan out Figure 13 Remove all wires and undo screws from both fixing brackets Remove valve Figure 12 To remove the gas valve disconnect the main gas pipe from the left side and the burner pipe from the right SERVICING AND MAINTENANCE continued 16 ...

Page 17: ...one in each corner SERVICING AND MAINTENANCE continued 17 After carrying out service or replacing parts reverse the above processes to reinstate the components Prior to lighting ensure there are no gas leaks If your Captiva Island fireplace still does not operate correctly consult your dealer All service and repairs should be performed by an authorised person or company All spare parts and optiona...

Page 18: ...OL ASSEMBLY Inlet Test Pressure Point Outet Test Pressure Point Adjustment for High Adjustment for Low Gas Outlet Gas Inlet Gas Control Valve Module Box Remote Control Module Sensor PARTS LIST Remote Control 18 ...

Page 19: ...CAPTIVA ISLAND FLUE TERMINATION COWLS REGULATIONS Balanced Flue 19 ...

Page 20: ...on to turn the thermostat on and off Setting the day of the week and time With the thermostat off press and hold the T button for 2 seconds or longer to initiate programming the time Time the hour setting and AM PM will flash Setting the hour function Press and release the s or t button to increase or decrease the hour setting by 1 hour Press OK to accept Setting the minute function Press and rele...

Page 21: ...or Saturday Sunday The entire week can also have the same program Alternatively a weekday or weekend program can be set with individual programs for the remaining days The suggested period settings for each day s are Period 1 morning Period 2 daytime Period 3 evening Period 4 night time To begin programming With the thermostat off press and hold the P button for 2 seconds or longer to initiate pro...

Page 22: ...nds Please ensure that AM PM is set correctly Press OK to accept The minute setting will now flash Adjust the minute setting similarly using s or t button Press OK to accept Setting the temperature The temperature setting will now flash Press and release the s or t button to increase or decrease the temperature setting by 1 C Press and hold the s or t button for 2 seconds or longer to increase or ...

Page 23: ...EMPERATURE HIGH LIMIT GAS VALVE MODULATION COIL RED BROWN BLUE ORANGE GREEN YELLOW GREEN YELLOW GREEN YELLOW BLACK MED WHITE LOW BLUE GREEN YELLOW PURPLE WHITE BLUE GREEN YELLOW PURPLE WHITE BLUE BLUE BROWN BROWN BLUE BROWN BLUE RED MILLENIUM REMOTE CONTROL MODULE N N A LO MED TH1 TH2 MOD MOD 23 ...

Page 24: ...eelong hotmail com au Sydney NSW Showroom 546 Pacific Highway Chatswood NSW 2067 Ph 02 8905 0189 Fax 02 8905 0192 E mail info realflame com au Miranda NSW Showroom 36 Kareena Rd Miranda NSW 2228 Ph 02 8513 6202 Fax 02 9520 1974 E mail fireplace realflamesouth com au Adelaide SA Showroom 173 175 Magill Rd Norwood SA 5067 Ph 08 8132 0371 Fax 08 8132 1687 E mail realflamesa iprimus com au Milton QLD ...