ReadyNet QX300 How-To Download Page 3

- Power adapter

- Factory Settings

Power Adapter

1. Connect the Network and Power

Connect the DC plug on the power adapter to the DC port on the device and connect the other

end of the power adapter into an electrical power outlet.

Connect the ethernet cable between the Internet port on the device and the network port on a

router or switch to access LAN.

IP Address

1. Find out your ReadyNet QX300 IP Address

For ReadyNet QX300 lift the handset and enter ****, choose "1" and then choose "2", the IP

address will be recited.

Factory Settings

1. Reset to factory settings

This step is not required for out-of-the-box devices, however, if the device has been already used
then it is a must.

For ReadyNet QX300 press the reset button at the front of your router device for 10 seconds,

this will wipe out any changes made to your router.

Device will be reset to the factory default settings.

Wait sometime prior for device to reboot.

NOTE: 

 Do not unplug or remove power to the device while it is updating firmware and

configurations.

Registering Device

This chapter describes how to identify ReadyNet QX300 device model, requirements that must
be met and how to register the device using manual configuration or auto provisioning.

The following topics are covered:

- Manual Configuration

- Auto Provisioning

Manual Configuration

This chapter describes how to set UAD settings, create PBXware extension and register the
device.

Summary of Contents for QX300

Page 1: ...om Bicom Systems Wiki Contents 1 Introduction How to use ReadyNet QX300 with PBXware 1 1 Requirements 2 Installation 2 1 Power Adapter 2 2 IP Address 2 3 Factory Settings 3 Registering Device 3 1 Manu...

Page 2: ...u should check Although different device models can have exactly the same requirements and installation procedure device models can also have significantly different requirements and installation proc...

Page 3: ...box devices however if the device has been already used then it is a must For ReadyNet QX300 press the reset button at the front of your router device for 10 seconds this will wipe out any changes ma...

Page 4: ...edit icon corresponding to your ReadyNet QX300 UAD phone Make sure Status is set to Active Auto provisioning is set to No and DHCP is set to Yes UAD settings Click on the Save button to save changes C...

Page 5: ...s auto generated in order to allow the UAD to successfully register with the system The secret value can be changed however it is STRONGLY recommended not to change the system generated value to a sim...

Page 6: ...ubscriber Information section PBXware extension number Example 1003 Password The Secret of the extension as received in the e mail associated with this extension Example _ Z4M3 Ts9y7 A password is gen...

Page 7: ...Save button to save changes Creating Extension 1 Add Extension Navigate to Extensions Click on Add Extension The standard options window will be shown below Select ReadyNet QX300 device model from th...

Page 8: ...process has been initiated by user DHCP server will instruct the device where from to pickup appropriate configuration file If everything is done as above described you should have successfully regist...

Page 9: ...oip bicomsystems com MA conf Example for IP Address tftp 192 168 1 10 MA conf Make sure that Option 66 is DISABLED Click on the Save Apply button Click on the Reboot button If everything is done as ab...