Error messages
All error messages begin with the "!" exclamation mark.
Error Message
Description
!Syntax error
There was syntax error in the previous command.
!Reach PoE Tester...
There is an internal version error in this unit.
! invalid port value
The value given with the port prefix was not valid.
! invalid group value
The value given with the group prefix was not
valid.
! run calibration first
If the power-on calibration was interrupted, and the
set or class commands are used, this error message
is generated.
! invalid class value
The CLASS command argument is not 0 thru 4.
! Error: set limit is
1400mA
The argument for the SET command is too large.
!p%d Autocal FAIL
Autocalibrate has failed on the specified port.
! unsupported baud rate
Baud rate argument is invalid
! invalid arguments
Command argument(s) are invalid
(other messages)
There are other messages that begin with an
exclamation point that are internal errors. If these
appear, the unit needs to be repaired.