The 

T-two

 unit features two separate configuration menus: The first menu is identified by the initials 

P.0 

and includes all the functions necessary for setting up the device hardware, whereas the second, 

which  is  identified  by  the  initials 

P.1

,  can  be  used  to  set-up  the  tension  regulator  operating 

parameters.  
When  the  user  selects  a  menu  without  accessing  it,  the  display  indicates  some  useful  additional 
information  about  the  selected  menu.  To  select  the  menu,  press  and  hold  the 

     

key  for 

approximately 3 seconds the letter 

P.

 Appears on the display, followed by the menu identification 

number;

 

press the 

+

 / 

 

keys to scroll to the desired menu, then press 

   

to select it and continue 

pressing to access the functions menu. 

 

 

Information indicated on the display 

The following table lists the information that may appear on the display, depending on which menu 
has been selected. 

 

Key pressed

 

Menu P. 0

 

Menu P. 1 

None

 

Firmware Version

 

Tension (kg)/Position (%)

 

Setpoint 

 

PID regulator state * 

+

 

and

 

 

  

and

 

+

 

Current (A) supplied by AO3 

 

* For a list of the states, see the table on page 4

    

 
 
 

Programming keypad 

 

Red, 3-figure display 

 

Summary of Contents for T-two

Page 1: ...ENG T two Tension control with load cells or dancer roll USER S MANUAL...

Page 2: ......

Page 3: ...nction 13 Integral regulator in DEC state 9 Function 14 Derivative regulator in DEC state 9 Function 16 Proportional regulator in STOP state 9 Function 17 Derivative regulator in STOP state 9 Function...

Page 4: ...ards adopted in the member state in which it was installed WEEE Waste Electrical and Electronic Equipment may be intended for individual collective or mixed collection and recovery systems at designat...

Page 5: ...n occurs after the instrument has been set to the ZERO state in order to change the reel the regulator will restart at the torque value set up in F 1 irrespective of the F 48 setting this also happens...

Page 6: ...about the selected menu To select the menu press and hold the key for approximately 3 seconds the letter P Appears on the display followed by the menu identification number press the keys to scroll to...

Page 7: ...the ACC and DEC remote contacts are active as illustrated in diagram 1 below By using the ACC F 6 and DEC F 11 state delays it is possible use a different set of parameters for a predetermined period...

Page 8: ...or select the last function and press the key after approx 3 seconds the unit will exit the menu and the data will be saved Regulator set up and parameters menu P 1 Function ID Description Parameter n...

Page 9: ...CES 0 0 1 0 02 0 F 38 Remote setpoint acquisition SETPOINT_ACQ_MODE OFF On OFF F 39 Remote setpoint filter SETPOINT_FILTER 0 100 80 F 40 Remote dancer roll air pressure acquisition PRESSURE_ACQ_MODE O...

Page 10: ...ate This parameter together with the proportional and derivative parameters acts on the regulation when the machine is operating at the working speed AUTO state Decrease the value of the integral para...

Page 11: ...when the machine is in the acceleration phase ACC state Refer to F 4 for a description of the parameter Press to access the function the display indicates the corresponding value Press to set up the...

Page 12: ...ortional regulator in STOP state This parameter together with the derivative parameter acts on the regulation when the machine is stationary STOP state Refer to F 3 for a description of the parameter...

Page 13: ...position exceeds the alarm 1 threshold F 34 whereas Alarm 2 is activated when the tension or the position falls below the alarm 2 threshold F 35 b A Alarm 1 is activated when the tension or the positi...

Page 14: ...tes the corresponding value Press to set up the desired threshold value Press to confirm Function 36 Tension Position reading filter During normal operation the unit displays the acquired tension or p...

Page 15: ...igital filter in order to obtain a stable signal that is free from unwanted variations The higher the filter setting the more the signal is filtered Press to access the function the display indicates...

Page 16: ...lay the current Admin password Function 98 Saving the Admin password To prevent the user or unauthorised personnel from modifying the settings in the regulator set up and parameters menu you can use t...

Page 17: ...tly The guarantee includes spare parts and labour It does not include shipment costs for device delivery or recall The guarantee is invalidated by Improper use of the device Incorrect installation Fau...

Page 18: ......

Page 19: ......

Page 20: ...dustriali Via Firenze 3 20060 BUSSERO MI ITALY Fax 39 02 95 03 89 86 Technical support Tel 39 02 95 24 30 300 E mail support re spa com Sales support Tel 39 02 95 24 30 200 E mail sales re spa com www...

Reviews: