ACCESSORIES
Model RLC-10R
Remote Level Control Rotary Encoder
LINEAR
AUDIO LEVEL
GND
+24 VDC
PULSE DOWN
MODE SELECT
RAMP OUT
RAMP IN
PULSE UP
RLC-10R
OBSERVE LEVEL ON LEDs
ADJUST LEVEL ON KNOB
CONNECTIONS TO ST-VCA3
(SAME WIRING MAY BE USED FOR
OEM OR RU-VCA 0 TO 10V CONTROL)
(SHOWN IN +15V PULSE CONNECTION MODE)
CONNECTIONS TO RU-VCA2A or RU-VCA6A
PARALLEL CONNECTIONS
REMOTE CONTROLS
TO ADDITIONAL RLC-10R
GND
+24 VDC
PULSE DOWN
MODE SELECT
RAMP IN
PULSE UP
RAMP OUT
RLC-10R
CONNECTION MODE)
(SHOWN IN OPEN-COLLECTOR
CONNECTIONS TO OEM EQUIP
GND
UP PULSE
DOWN PULSE
0 TO 10V OUT
OEM EQUIP
24VDC SUPPLY
PRESET
EQ
P
M
A
R
10
V
N
D
U
P
10 V
0 TO
P
U
D
N
R
A
M
P
24V
IN
OUT
EXTERNAL
CONTROL
DATA
SETTINGS
E
D
O
M
MOM
0 TO 10 VDC
C
T
R
L
L
E
V
E
L
MASTER
SLAVE
LAST
POWER UP
IN 1
IN 2
OUT 2
OUT 1
CONTROL
AUDIO
PWR
VDC
24
RDL
MADE IN U.S.A.
RU-VCA2A
+24 VDC
GND
PULSE DOWN
RAMP OUT
PULSE UP
RAMP IN
MODE SELECT
RLC-10R
E
E
V
U
O PWR IN
T
L
10V
L
C
R
T
LINE IN OUTPUT
LINE
L
G
I
MIC IN
A
N
NOTE: Wiring between VCA and RLC-10R must be electrically shielded, either by installation in
a metal conduit or using shielded cable. When shielded cable is used without conduit (or in
nonmetallic conduit), the shield should be connected to the RLC-10R mounting enclosure.
TYPICAL PERFORMANCE
Ramp output:
0 to 10 Vdc
Pulse outputs (2):
PULSE UP
,
PULSE DOWN
(programmable open collector, or +15 V pulse)
Pulse output current:
20 mA (open collector)
Display RAMP IN input resistance:
200 k
Display input voltage:
0 to 10 Vdc
Rotations, approximate min-to-max:
5 (slow rotation, no acceleration)
3 (medium rotation, with acceleration)
1 (fast rotation counterclockwise, anti-feedback mode)
Power Requirement:
24 Vdc @ 50
mA, Ground-referenced
Overall Dimensions:
Height:
4.9 in.
12.44 cm
Width:
3.4 in.
8.63 cm
Depth:
1.6 in.
4.06 cm
Installation/Operation
EN55103-1 E1-E5; EN55103-2 E1-E4
Typical Performance reflects product at publication time
exclusive of EMC data, if any, supplied with product.
Specifications are subject to change without notice.
891-9115E
Radio Design Labs Technical Support Centers
U.S.A. (800) 933-1780, (928) 778-3554; Fax: (928) 778-3506
Europe [NH Amsterdam] (++31) 20-6238 983; Fax: (++31) 20-6225-287
NOTE: This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rule. These limits are designed to
provide reasonable protection against harmful interference
in a residential installation. The equipment generates,
uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions,
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception,
which can be determined by turning the equipment off an
on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment
and receiver
Connect the equipment into an outlet on a circuit
different from that which the receiver is
connected.
Consult the dealer or an experienced radio/TV
technician for help.