Programming the panel for radio 
communication

The internal radio transmitter is able to report the 
following telemetry conditions:

Step 1

Programme the “T” parameter in the “MS 1 
Protocol” screen to “T=2” - RDC radio transmitter is 
installed.

Step 2

In the MS 1 & 2 “Options” in the “Communication” 
menu, all the parameters are disabled (‘-‘) by factory 
default (including after panel initializing). Enable 
ONLY the required telemetries with careful 
reference to the note below.

NB: ONLY ENABLE CRITICAL 
TELEMETRIES. Indiscriminate activation 
of non-critical telemetries (including 
Open/Close) for radio communication can 
lead to network congestion and may 
result in critical signals being lost. Panel 
specific telemeteries such as 

keypad 

failure and restore, phone-line failure and 
restore, siren failure and restore etc. 

should NEVER be activated. 

!

  Up to 4 partitions are supported / reported

!

  Up to 31 zones are reported 

(zone 32 reserved for universal or unknown zone)

 

!

  Up to 15 users / key holders are reported

(user 16 reserved for universal or unknown user)

!

  Only battery low and AC fail restorals are reported

!

  All standard RDC type telemetries are reported

TX-7serial Pima - 

Installation Instructions

Transmitter standby -

 

battery voltage correct

Transmitting
Mains fail
Battery voltage too low for normal operation
Low battery, but still able to operate
Battery over voltage
Incorrectly programmed

LED indicates transmitter conditions:

ADI Support

0800 234 468

RDC 24hr Standby

082 444 7176

Squeeze the 
lid firmly on 
both sides just 
below the 
mounting holes 
to remove the lid

Recommended mounting
screws and plugs

M4.5 x 30 mm 
countersunk head

self tapping

6 x 35 mm

Mounting screws and
plugs not included

www.radiodata.co.za

Connect the transmitter 
to the panel by connecting 
the 4-way connector to JP4 
on the PIMA panel.

DC power - connect directly 
to system battery

TRANSMIT

KEYPAD

SERIAL

JP4

JP2

JP1

Rev 115 1211