RCT Power Power Battery 11.5 Manual Download Page 20

16 

  Mounting 

4.2

 

Mounting Procedure:  

 

First place, the ground plate to the place where the 
Power Battery to stand later. Keep a distance of 
20cm away from the wall. 

The side marked by the arrow has to stand 
opposite the wall.  

 

 

 

Next, place a Power Battery Stack with the included 
mounting handle on the ground plate, so that the 
connections look towards the wall.

 

 

Make sure that no cables are pinched during 
assembly and that the parts of the Power Battery 
are parallel to the ground. 

Summary of Contents for Power Battery 11.5

Page 1: ...MANUAL Power Battery 5 7 7 6 9 6 11 5 EN...

Page 2: ...ecuted We reserve the right to make technical changes that improve the equipment or increase the safety standard even without a separate announcement Responsible for content RCT Power GmbH This user m...

Page 3: ...ATION 14 Place of installation 14 4 1 Mounting 16 4 2 5 ELECTRICAL CONNECTION 18 Wiring Power Battery 18 5 1 5 1 1 Protective earth connection 18 5 1 2 Communication connection 19 5 1 3 DC connection...

Page 4: ...your PV system The battery system is equipped with a safe and efficient battery management technology Power Battery Master Keep this manual in a convenient place for future reference Declaration of c...

Page 5: ...andards or codes Warranty conditions come enclosed with the device No warranties can be derived from this document Note The Power Battery is a Class A device Symbols and note explanation 1 2 Important...

Page 6: ...derstand the functions of a battery system and know how it operates They are familiar with lithium iron phosphate LiFePO 4 batteries They have read and understood the documents shipped with the device...

Page 7: ...omponents of the Power Battery Risk of death or serious injury due to electric arc Installations service and maintenance work may only be carried out by Qualified electrician Do not immerse the produc...

Page 8: ...l injury or material damage the inverter and the battery must only be installed wired connected commissioned maintained and serviced by qualified personnel Explosion risk It is strictly forbidden to c...

Page 9: ...he intended usage is considered misuse RCT Power GmbH shall not be liable for any damage resulting from misuse Any misuse will cause the termination of the warranty guarantee and general liability of...

Page 10: ...for which the transport company is generally responsible If you notice any damage to the packaging or the PowerBattery please immediately inform the transport company Check the content for completenes...

Page 11: ...r if any damage is detected 1 2 3 4 5 6 Fig 3 2 1 Delivery contents of Power Battery Master Item Description 1 1x Power Battery Master 2 1x Wall bracket used to fix the upper part of the battery onto...

Page 12: ...Battery Stack for visible damages Contact your supplier if the delivery is incomplete or damaged Do not install connect and operate the Power Battery Stack if any damage is detected 1 2 Fig 3 2 2 Deli...

Page 13: ...Item Description 1 Power Battery Master 2 Power Battery Stack 3 6 Units 3 Floor plate 4 Wall bracket 5 DC connection 6 Protective conductor 7 RJ45 interface communication 8 Terminal resistor 9 Levelin...

Page 14: ...tion to the Power Storage 4 PE connection 5 On Off switch 6 Intern DC connection for the Power Battery Stack 7 Output DC for DC battery connection to the Power Storage Batt 8 CAN interface communicati...

Page 15: ...Master 3 Fuse cover 4 RJ45 interface communication to the Power Battery Stack or Power Battery Master 5 PE connection 6 DC connection for the Power Battery Stack or Power Battery Master 7 RJ45 interf...

Page 16: ...ption 1 Serial Number 2 Technical Data 3 Symbols This symbol indicates that the user manual must be read and understood before putting the unit into operation Warning of electrical voltage DC voltage...

Page 17: ...erstood before putting the unit into operation Warning of electrical voltage DC voltage present in cables and inner parts of Power Battery Stack Danger of electrostatic dis charging and gas explosion...

Page 18: ...tacks is more than 18kg The location must be made of flame retardant material Do not place the Power Battery in potentially explosive atmosphere Keep away from flammable materials Only install the Pow...

Page 19: ...m clearance to allow sufficient cooling air convection Do not place battery inside a closed cabinet Make sure that there is sufficient air convection around the battery Overheating of the battery due...

Page 20: ...0cm away from the wall The side marked by the arrow has to stand opposite the wall Next place a Power Battery Stack with the included mounting handle on the ground plate so that the connections look t...

Page 21: ...To attach the wall bracket remove the two screws on the top stack preferred Torx T20 First take the wall bracket and attach it to the top Power Battery Stack After the wall bracket is attached slide c...

Page 22: ...0 After the Power Battery has been built up the cabling on the back of the housing can be started Pull away the battery from the wall to get enough space for wiring 5 1 1 Protective earth connection T...

Page 23: ...arth connection on the housing 5 1 2 Communication connection For the communication between the individual modules use the enclosed patch cables and terminating resistor First connect the terminating...

Page 24: ...ble from the Power Battery Master in the positive connector of the lowest Power Battery Stack It is advisable to route the dc cable between the case and the dc cable from the stack Plug the negative D...

Page 25: ...tery Master is suitable for min and maximum system voltage and system voltage does not exceed maximum input of inverter Any kind of soiling dust moisture etc has a negative effect on the connector sys...

Page 26: ...nnecting the cable Turn the plug on 5 2 2 Preparation for wiring to the inverter Risk of death or serious injury due to electric shock Only by RCT Power GmbH specified and certificated battery systems...

Page 27: ...tching washers with minimum outer diameter of 15 mm Move the Power Battery carefully to the wall and fix it to the wall by using two screws over the wall bracket After the battery is fixed turn the ne...

Page 28: ...erial Too high storage temperature results in faster self discharge and premature aging To avoid damage store the Power Battery Stack in an environment with relative humidity 85 no corrosive gas and a...

Page 29: ...n the deployment location when installing or operating the product Ignoring safety warnings and instructions contained in all documents relevant to the product Installing or operating the product unde...

Page 30: ...ress E Mail Phone Power Battery Power Battery Serial number Date of install Power Battery Master Power Battery Stack 1 9 Power Battery Stack 1 9 Power Battery Stack 1 9 Power Battery Stack 1 9 Power B...

Page 31: ...000W Standby consumption 5 W INTERFACE Power storage interface CAN GENERAL Battery technology LiFeP04 Dimensions height x width x depth 0 83x0 34x0 34m 1 06x0 34x0 34m 1 29x0 34x0 34m 1 52x0 34x0 34m...

Page 32: ...RCT Power GmbH Line Eid Str 1 78467 Konstanz Deutschland Tel 49 0 7531 996 77 0 Mail info at rct power com Internet www rct power com 07 2017...