background image

 

Rx65 - Programming v610 

 

 

 
PRODUCT: 

Rx65

 

1. PROGRAMMING APPROACH: 

Settings in the Rx can be changed using a standard Tx or a special Programa device (Prog1 or Prog3). All use 
the structure in the table below. One output or feature (ie: one row in the table) is programmed at a time. The 
first two columns usually select the output and the other three change its characteristics. 

[KEYWORDS]

 

provide links to detailed descriptions of each feature. The 'Tx' column is for 'Tx Change' mode.  
Options are organised into menus usually relating to a type of output. 
Level 1 and 2 usually select the output number (eg: 2-flash for 'P' then 4-flash for 'P4'). 
You select a row in the table above and make up to 5 choices, one for each level.  
 
3. INVOKING PROGRAMMING WITH: 

TX20 

TX-2s 

TX-4s 

                                  1.  Switch TX ON.  2.  Press and hold F1 & F2. 
                          3. Switch RX ON wait for fast flicker.  4. Release F1 & F2. 

 

 

 

Make choices: 

6. The led flashes the setting for the first 'Level' (eg: 1-flash = Motor output 'H'). 

7. Yes = push the Direction switch 

forward (to top of Tx) to accept this 

option and advance to next Level. 

7. Yes = Twist small valve gear 

knob to right & back to accept this 

option & advance to next Level. 

7. Yes = Twist small valve gear 

knob to right & back to accept this 

option & advance to next Level. 

8. No = pull the Direction switch 

back (to bottom of Tx) to see next 

option for same Level. 

8. No = Twist small valve gear 

knob to left & back to see next 

option for same Level. 

8. No = Twist small valve gear 

knob to left & back to see next 

option for same Level. 

9. Continue through all Levels until Led comes on solid.  

Settings are saved automatically at the end so switch off at any time to abort. 

Say 'yes' to every item to just see what is currently set. 

 

Changing 'P2' from Ch4 to Ch5. 
Level 1: 3-flash = P 
Level 2: 2-flash = P2 
Level 3: 1-flash = Servo 
Level 4: 5-flash = Ch5  

 

Summary of Contents for Rx65

Page 1: ...F1 F2 3 Switch RX ON wait for fast flicker 4 Release F1 F2 Make choices 6 The led flashes the setting for the first Level eg 1 flash Motor output H 7 Yes push the Direction switch forward to top of Tx to accept this option and advance to next Level 7 Yes Twist small valve gear knob to right back to accept this option advance to next Level 7 Yes Twist small valve gear knob to right back to accept t...

Page 2: ... flash Tens x10 0 flash 0 0 9 flash Ones x1 0 flash 0 Minimum power level 0 for full power range 1 flash 1 flash H1 5 flash Max power 0 100 M_MAX 0 10 flash Tens x10 0 flash 0 0 9 flash Ones x1 0 flash 0 Maximum power level 100 for full power range 1 flash 1 flash H1 6 flash Motor Reverse M_REV 1 flash not reversed 2 flash reversed 1 flash 1 flash H1 7 flash PWM Frequency M_PWM 1 flash 16 kHz 2 fl...

Page 3: ...l is low 2 2 flash 1 flash P1 4 flash Servo mixed 2 channel mix SERVO_4a 1 10 flash Primary Ch 1 flash 0 mix 2 flash 12 5 mix 3 flash 25 mix 4 flash 50 mix 5 flash 100 mix P1 P2 used as a pair Primary channel and Mix is set with P1 2 2 flash 2 flash P2 4 flash Servo mixed 2 channel mix SERVO_4b 1 10 flash Secondary Ch 1 flash not reversed 2 flash reversed P1 P2 used as a pair Secondary channel and...

Page 4: ... LATCH_1 1 10 flash Channel Normally off 1 flash 3v when Ch is low 2 flash 0v when Ch is mid high Normally on 3 flash 0v when Ch is low 4 flash 3v when Ch is mid high 1 channel controls 1 2 outputs Each move toggles on off 3 4 flash from v610 5 2 3 flash 1 4 flash P1 P4 3 flash On Off led latching LATCH_2 1 10 flash Channel 1 flash high 2s on off 2 flash high 2s on off 3 flash low 2s on off 4 flas...

Page 5: ...top close throttle to rearm from v610 7 2 3 flash 1 4 flash P1 P4 8 flash Stop Reverse BUFFER2 Time to stop 1 6 flash 1 6 seconds Pause time 1 6 flash 1 6 seconds 7 flash Random 1 6s ONE pad can detect external trigger Action Stop Pause Reverse auto from v610 7 2 Menu 4 Infrared Pad number Output type Channel Position 4 flash 1 4 flash P1 P4 IR type IR 1 flash IR1 Manual 2 flash IR2 Static Addr 3 ...

Page 6: ...flash Failsafe Cruise Control FAIL Time to stop after signal loss 1 4 flash 1 4s 5 flash Sleep time Time to kill outputs after signal loss Use Sleep time for cruise control with transmitter switched off 5 flash 5 flash Emergency Stop STOP 1 flash Disabled 2 flash Ch low stop 3 flash Ch high stop 1 10 flash Channel Manual trigger over radio Quicker than failsafe 2 5 flash 6 flash Binding 1 flash Au...

Page 7: ...DELAY 1 flash Instant 2 flash 0 5s 3 flash 1s 4 flash 1 5s 5 flash 2s 6 flash 2 flash Rx Change channel S_RXCH 1 10 flash Channel to select Rx 2 6 flash 3 flash Action when deselected S_STOP_GO 1 flash stop 2 flash continue Continue throttle may be open or closed 6 flash 4 flash Tx Change channel S_TXCH 1 10 flash Channel to change Tx 2 6 flash 5 flash Copy profile S_COPY 1 flash Copy 1 to 2 2 fla...

Page 8: ... Tx22 7 flash 3 flash Reset current variant 1 flash No reset 2 flash FACTORY RESET 7 3 2 Reset ...

Reviews: