Leak Testing 

 

NEVER USE AN OPEN FLAME TO CHECK FOR LEAKS. 

 
All gas piping and connections must be tested for leaks after installation or service. All 
leaks must be corrected immediately. Remember-before exchanging an empty bottle 
for a new one, make sure all control valves are in the “off” position. 
 
With the LP regulator connected to tank and grill and the grill knobs turned to OFF. Open 
the valve on the tank. Test for leaks by applying liquid soap solution to all joints. Bubbles 
forming indicate gas leak. Fix gas leak before continuing use. 

 

 
Burner Adjustments 

 

Every grill is thoroughly checked for proper lighting and burner flame pattern. Conditions at 
the location may necessitate minor adjustment of the burner air intake, if the flames 
are not steady/stable as shown in the figure. 
 

 

The flame should be full length of the burner, blue and stable. The air intake (if applicable) 
should be adjusted  ONLY if the flame is lifting off of the ports or has noticeable 
amounts of yellow in the flame. 

18 | 

P a g e

 

 

Summary of Contents for RJC26a

Page 1: ...ner s Manual For Outdoor Use Only Installation Operation Maintenance Instructions Parts List Models RJC26a RJC32a RON30a RON38a RON42a These grills are tested and certified to the ANSI Z21 58 CSA 1 6...

Page 2: ...Proud Owner Congratulations on the purchase of this high quality high performance grill Read this manual carefully to understand all the instructions about how to install operate and maintain for opt...

Page 3: ...1 natural gas and propane installation code WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage and void the warranty Read the installation o...

Page 4: ...his unit should be installed in accordance with the National Fuel Gas Code No Z223 1 CAN CGA B149 1 natural gas installation code or CAN CGA B149 2 propane installation code CALIFORNIA PROPOSITION 65...

Page 5: ...the grill or any stainless components doors drawers etc Wind Guard WARNING Your RCS grill should NOT be installed with the back of the grill facing frequent prevailing winds like a large body of water...

Page 6: ...lyvinyl covers are available that have been specially designed for this range of barbecues Allow clear access to the entire gas supply hose and regulator Maintenance Access When your barbecue is insta...

Page 7: ...7 P a g e...

Page 8: ...get close to the grill while in use Items of interest to children should not be stored in or around the grill in the cabinet or in the masonry enclosure Portions of the grill can be extremely hot whi...

Page 9: ...supplied manual gas shut off valve must be installed in an easily accessible location in the gas supply line ahead of the pressure regulator 4 W C The outdoor cooking gas appliance and its individual...

Page 10: ...Appliance pressure 10 W C Inlet pressure 11 14 W C Purchase a standard 20 LB LP tank with QCC 1 fitting and an approved hose and regulator the RCS RONHK Available From Your RCS Dealer Assemble pipe ho...

Page 11: ...is not in use the gas must be turned off at the supply cylinder Cylinder must be stored outdoors out of reach of children and must not be stored in a building garage or any other enclosed area A dent...

Page 12: ...es and back of the unit to adjacent vertical combustible construction extending above top of unit 24 inches from side and 15 inches from back Do not locate under any overhead combustible construction...

Page 13: ...ation only Follow the cut out dimensions as shown ALL outdoor kitchen cabinets MUST include ventilation We recommend 12 square inches of opening for each running 4 feet of counter top See Item RVNT1 f...

Page 14: ...Model A Width B Depth C Height RJC26a 23 1 2 21 8 RJC32a 30 5 8 21 8 RON30a 33 20 11 RON38a 41 20 11 RON42a 45 20 11 Model Lid Clearance RJC26a 25 RJC32a 25 RON30a 23 RON38a 23 RON42a 23 14 P a g e...

Page 15: ...15 P a g e...

Page 16: ...l codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 Keep any electrical supply cord and fuel supply hose away from any heated surface HALOGEN LIGHT The RON...

Page 17: ...Electrical Wire Diagram 17 P a g e...

Page 18: ...e tank Test for leaks by applying liquid soap solution to all joints Bubbles forming indicate gas leak Fix gas leak before continuing use Burner Adjustments Every grill is thoroughly checked for prope...

Page 19: ...ou smell gas check for leaks If odor continues immediately call for service Keep your face and body away from the grill top when lighting Grill Burner Lighting 1 Open lid before lighting Make sure all...

Page 20: ...serie Not included with all models Plug in the motor power cord to a properly grounded receptacle Rotisserie cooking can be done with grill burners as well as with the Rotisserie burner ON KEEP THE MO...

Page 21: ...Use other burner settings to create temperatures to fit your personal cooking preferences Temperatures may vary with outside temperature and wind conditions Remember your heat indicator is just that a...

Page 22: ...e area clear and free from combustible materials gasoline and other flammable vapors and liquids Do not obstruct the flow of combustion and air ventilation Keep the ventilation opening s of the cylind...

Page 23: ...ont of the regulator pulling out the plastic orifice flipping it over and replacing it Tighten the large nut and you re ready to go This step does not apply to the LP hose and regulator set only the s...

Page 24: ...emely gentle when removing 8 Replace new change out orifice repeat for all burners When re installing orifice do not over tighten or you will strip the brass fitting Little pressure is needed 9 Replac...

Page 25: ...urners See electrode for visible damage replace if damaged Improper burner flame Check burner gas inlet area for blockage Check orifice hoods for any clogging and clean Adjust air shutter if necessary...