Note: The OEM Module installation is the same as the standard sensor kit, with 
the exception that it provides a separate lead (yellow) to activate your own relay 
or lamp. 

 

LIMITED WARRANTY 

 

RCI Technologies hereby warrants the RCI Sensor and Indicator to the original 
purchaser when installed following the written instructions provided by RCI at 
the time of purchase, 

WARRANTY OFFERED HEREIN APPLIES ONLY 

TO DEFECTS IN MATERIALS AND WORKMANSHIP 

for a period of one 

(1) year, 12 months from the date of purchase.  The decision to repair or replace 
parts covered herein to be at the sole discretion of RCI Technologies. 
 

WARNING: 

 

1.

 

BOTH THE PURIFIER AND THE INDICATOR MUST BE GROUNDED. 

2.

 

ALWAYS  USE  A  WIRE  SIZE  THAT  IS  RATED  TO  HANDLE  THE 
ELECTRIC LOAD (#16 OR HEAVIER WIRE IS REQUIRED) 

3.

 

GOOD  ELECTRICAL  CONNECTIONS  ARE  IMPORTANT  FOR 
MAINTAINING ACCURATE SENSOR READINGS, AND AVOID HEAT 
BUILD UP IN THE WIRING.  

4.

 

CHECK FOR FUEL LEAKS. 

 

The RCI water sensor and indicator has been designed to operate when the RCI 
fuel purifier is in need of purging.  A buzzer followed by a red indicator light 
will come on when the water level in the purifier reaches the sensor level.  The 
buzzer will last 10 seconds and the light will stay on until the unit is purged. 
 

INSTALLATION:

 

1.

 

Drain all fuel from the purifier, making sure it is empty. 

2.

 

Remove the factory-installed plug from the sensor port. 

3.

 

Wrap Teflon tape around the threads of the sensor probe (about 4 layers). 

4.

 

Carefully insert the probe into the sensor port on the purifier, making sure 
the threads are not crossed, and tighten the sensor probe.  

5.

 

Insert the ground ring over the drain plug (or heater when equipped), then 
rewrap with Teflon tape and reinstall. Connect ground wire to ground ring. 

6.

 

Refill the purifier with clean fuel.  Check for fuel leaks. 

 

     You are now ready to proceed with the electrical connections. 

 

1.

 

Install  the  indicator  gauge  on  the  dashboard,  control  panel  or  other 
convenient location. 

2.

 

Cut  an  appropriate  length  of  wire  from  the  wire  supplied,  or  purchase a 
sufficient length of #16 gauge wires to reach from the purifier to the back 
of the indicator light.  

3.

 

Connect the 

green

 wire from the probe to the wire running to the indicator 

light.  Use electrical tape on all wire connections. 

4.

 

Run the 

black

 ground wire from the indicator light to the ground. 

5.

 

Run the 

red

 wire from the indicator light to a fused power source.  It is 

suggested that the power source be controlled by the ignition key or switch 
so  that  power  is  supplied  to  the  indicator  only  when  the  equipment  is 
operating.  

 

PRECAUTION

: Check for fuel leaks. 

 

TESTING

:  

Remove green connector from probe and apply ground to the green lead.  Red 
LED  light  should  activate.    Remove  ground.  Alarm  should  restore.    Replace 
green connector to probe. Alarm is now ready. 
 
This completes the installation of your sensor probe and indicator light.  Start 
the engine and top off the fuel level in the purifier by depressing the air relief 
valve to remove all trapped air from the fuel system. 

 