RCI 960 Series Installation Download Page 1

1. Remove the components from the box and read

these instructions carefully in order to assemble
correctly.

2. Place the mortise cylinder (optional) 1-1/8" cylinder

length complete with straight or clover cam through
the 1-3/16" hole in the center of the aluminum face-
plate.

3. Mount the cylinder/switch bracket on the reverse

side of the faceplate (see below) making sure that 
the teeth are positioned inside the grooves along the
cylinder, then attach the cylinder nut to fasten.

4. Insert the switch(es) into the 1/2" holes located on

the bracket below the cylinder. For ideal installation
thread the top nut an 1/8" down and tighten bottom
nut using a 9/16" wrench.

5. Make wire connections as required (see wire 

connection figure below).

6. Fasten faceplate assembly to electrical box with the

tamperproof 6-32 machine screws supplied with the
spanner hand tool (also supplied).

4-3/4"

(120.6mm)

3" (76mm)

1-11/16" (N) (43mm)

1-1/2" (38mm)

27/32" (N)

(21.5mm)

CL

1/2" (13mm)

Switch Hole

(N) = Narrow Style 960N

1/4" (6.3mm)

2-3/4"

(70mm)

1-3/16"

(30mm)

Rear Profile

Optional (DPDT Switch)

Side Profile

Instructions

TAMPER-RESISTANT KEYSWITCH

960

I N S T A L L A T I O N

®

Red N/C

Black (Common)

Red N/O (Maintained)
Green N/O (Momentary)

(SPDT)

Wire Connection

©2011 RUTHERFORD CONTROLS INT’L CORP. WWW.RUTHERFORDCONTROLS.COM

USA: 2517 SQUADRON COURT, SUITE 104, VIRGINIA BEACH, VA 23453 • CANADA: 210 SHEARSON CRESCENT, CAMBRIDGE, ON  N1T 1J6 

PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-MAIL: [email protected] 

IS960

PCN110045

R07/11SH

Summary of Contents for 960 Series

Page 1: ...wrench 5 Make wire connections as required see wire connection figure below 6 Fasten faceplate assembly to electrical box with the tamperproof 6 32 machine screws supplied with the spanner hand tool also supplied 4 3 4 120 6mm 3 76mm 1 11 16 N 43mm 1 1 2 38mm 27 32 N 21 5mm C L 1 2 13mm Switch Hole N Narrow Style 960N 1 4 6 3mm 2 3 4 70mm 1 3 16 30mm Rear Profile Optional DPDT Switch Side Profile ...

Page 2: ... 1 4 2 7 8 1 3 16 Time Adjustment Knob Wire to Negative of Power Supply Black Wire Green Wire Red Wire Wire to Positive of Power Supply NOTE To wire LED for green light instead of red light disconnect red wire from switch point and connect green wire 960 Bi Color LED Installation Description Switch Mode Switch Configuration Switch Rating Standard Finish 960 MO Key Switch Momentary Action SPDT N O ...

Page 3: ...4VDC operation 2011 RUTHERFORD CONTROLS INT L CORP WWW RUTHERFORDCONTROLS COM USA 2517 SQUADRON COURT SUITE 104 VIRGINIA BEACH VA 23453 CANADA 210 SHEARSON CRESCENT CAMBRIDGE ON N1T 1J6 PHONE 1 800 265 6630 519 621 7651 FAX 1 800 482 9795 519 621 7939 E MAIL SALES RUTHERFORDCONTROLS COM ...

Page 4: ...of Wire Run ft Load Current 12V 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A 100 20 18 16 14 14 12 12 10 150 18 16 14 12 12 12 10 200 16 14 12 12 10 10 250 16 14 12 10 10 10 300 16 12 12 10 10 400 14 12 10 500 14 10 10 750 12 10 1000 10 1500 10 Wire Gauge Chart courtesy of Electronic Locking Devices by John L Schum 2011 RUTHERFORD CONTROLS INT L CORP WWW RUTHERFORDCONTROLS COM USA 2517 SQUADRON COURT SUI...

Reviews: