RCI 9320 Installation Download Page 2

9320/22 Easy Read-Prox

®

 Installation Instructions 

(Continued)

                                         Electrical Installation Instructions 

1. If installing using the Slimline Reader, reference Fig. 5. If installing using the Micro Reader, reference Fig. 6.

Black Wire 

Negative Power Input

Red Wire 

12VDC Positive Power Input 

Note: Unit requires a filtered and regulated power source for proper operation.

Green & Yellow Wires 

Lock Release Output. If electric locks are polarity conscious the yellow wire is positive.

Blue & Purple Wires  

Request to exit or remote release switch (normally open) momentary button may be connected for 

lock release to exit.

Switching Current 

500mA continuous, 750mA for up to 7 seconds.

2. Make electrical connections as per schematic below, removing clear plug-in connector on end.

Micro reader surface mounted onto wall using back plate. The 

plastic end cap is placed over the exposed end of the reader.

Micro reader surface mounted onto a hollow wall using the back 

plate. The plastic end cap is placed over the base plate.

Note: All installations must conform to local fire, National Building, and Life Safety Codes.

DC Filtered 

Regulated 

Power Supply

DC Filtered 

Regulated 

Power Supply

Electric Lock

Request to Exit Switch

Green (-)

Yellow (+)

Blue Wires

Black (-)

Red (+)

Electric Lock

Request to Exit Switch

Green (-)

Yellow (+)

Blue Wires

Black (-)

Red (+)

Fig. 5

Fig. 6

© 2014 RutheRfoRd ContRols Int’l | A doRMA GRoup CoMpAny

www.rutherfordcontrols.com • Phone: 1.800.265.6630 • fax: 1.800.482.9795 • e-mail: [email protected]

Blue & Purple Wires

Blue & Purple Wires

Fig. 3

Fig. 4