![RCI 9320 Installation Download Page 2](http://html.mh-extra.com/html/rci/9320/9320_installation_1423997002.webp)
9320/22 Easy Read-Prox
®
Installation Instructions
(Continued)
Electrical Installation Instructions
1. If installing using the Slimline Reader, reference Fig. 5. If installing using the Micro Reader, reference Fig. 6.
Black Wire
Negative Power Input
Red Wire
12VDC Positive Power Input
Note: Unit requires a filtered and regulated power source for proper operation.
Green & Yellow Wires
Lock Release Output. If electric locks are polarity conscious the yellow wire is positive.
Blue & Purple Wires
Request to exit or remote release switch (normally open) momentary button may be connected for
lock release to exit.
Switching Current
500mA continuous, 750mA for up to 7 seconds.
2. Make electrical connections as per schematic below, removing clear plug-in connector on end.
Micro reader surface mounted onto wall using back plate. The
plastic end cap is placed over the exposed end of the reader.
Micro reader surface mounted onto a hollow wall using the back
plate. The plastic end cap is placed over the base plate.
Note: All installations must conform to local fire, National Building, and Life Safety Codes.
DC Filtered
Regulated
Power Supply
DC Filtered
Regulated
Power Supply
Electric Lock
Request to Exit Switch
Green (-)
Yellow (+)
Blue Wires
Black (-)
Red (+)
Electric Lock
Request to Exit Switch
Green (-)
Yellow (+)
Blue Wires
Black (-)
Red (+)
Fig. 5
Fig. 6
© 2014 RutheRfoRd ContRols Int’l | A doRMA GRoup CoMpAny
www.rutherfordcontrols.com • Phone: 1.800.265.6630 • fax: 1.800.482.9795 • e-mail: [email protected]
Blue & Purple Wires
Blue & Purple Wires
Fig. 3
Fig. 4