RDNet CONNECTION

The system is equipped with an RDNet connection on board. Using an RDNet controller 
unit it is possible to:
- receive status information from the system (amplifiers status, signal levels, system  

 

 settings,…)

send commands to the system (mute, solo, change sensitivity, change setting, set user    

 eq,…)
See the RDNet user manual for details.

RDNet BY-PASS SWITCH

When the RDNet is present and the RDNet LINK LED is green the controller takes control 
over the module 

independently of the BY-PASS SWITCH position

.

When the 

RDNet is not present

, the BY-PASS switch act as follow:

 -

BY-PASS SWITCH pressed

 (LED ON): the system bypass the input board and reads 

the RDNet user settings (

last configuration saved

).

 -

BY-PASS SWITCH released 

(LED OFF): the system 

reads the input board

 and bypass 

the user setting eventually loaded ion the speaker (last configuration eventually saved).

TTS36-A DEFAULT CONFIGURATION

The TTS36-A 

factory default configuration

 (the configuration that the system reads if 

the BY-PASS switch is pressed) is the following:

Sensitivity 

+4 dBu

High pass  

30 Hz

Low pass  

90 Hz

Cardioid  

OFF

Delay  

0

Bypass  

OFF

User filters 

ALL FLAT

If the user set with RDNet a new configuration, the new configuration will be recalled 
when the BY-PASS switch is pressed. 

BY-PASS SWITCH 

RDNet 

BY-PASS LED  FUNCTION

ON 

ON 

ON 

Reads RDNet settings

OFF 

ON 

OFF 

Reads RDNet settings

ON 

OFF 

ON 

Reads last saved used configuration

OFF 

OFF 

OFF 

Reads input panel

RDNet

RDNet CONNECTION

RDNet BY-PASS SWITCH

TTS36-A 
DEFAULT CONFIGURATION

Summary of Contents for TTS36-A

Page 1: ...OWNER MANUAL TTS36 A HIGH OUTPUT ACTIVE SUBWOOFER ...

Page 2: ......

Page 3: ...3 ENGLISH ITALIANO LANGUAGE 4 13 ...

Page 4: ...scribed in this manual Contact your authorized service centre or qualified personnel should any of the following occur The product does not function or functions in an anomalous way The power cable has been damaged Objects or liquids have got in the unit The product has been subject to a heavy impact 5 If this product is not used for a long period disconnect the power cable 6 If this product begin...

Page 5: ...he maximum sound pressure level IMPORTANT NOTES To prevent the occurrence of noise on line signal cables use screened cables only and avoid putting them close to Equipment that produces high intensity electromagnetic fields Power cables Loudspeaker lines OPERATING PRECAUTIONS Place this product far from any heat sources and always ensure an adequate air circulation around it Do not overload this p...

Page 6: ...one of only a few loudspeaker manufacturers worldwide who have the ability to completely design and manufactures transducers speaker systems and amplification and control electronics Our 50 plus years heritage in Audio combined with our state of the art research and development and manufacturing processes allows us to seamlessly integrate all the ingredients to design and build TT Intensity The de...

Page 7: ... Hz This is really useful for indoor situations no very low frequencies that can create resonant sound or when all the power shall be used in the 45 Hz 100 Hz range XOVER 60 100 HZ Provides 24 dB octave low pass filtering at 80 Hz if released at 110 Hz if pressed The same crossover frequency in high pass is available from XOVER OUTPUT XLR TIME DELAY ENCODER This encoder provides a time delay setti...

Page 8: ...th the limit indicator red continuously Continuous operation with the RMS protection active can cause damages to the speaker CARDIOID SET UP SWITCH This switch provides a special equalisation and delay setting to create a cardioid pattern when the system is used in conjunction with two other TTS56 A modules BY PASS SWITCH Pressing this switch it is possible to by pass the RDNet user setting preloa...

Page 9: ...diately after the show Now you can turn ON the speaker and adjust the volume control to a proper level The delay is expressed in meters The delay resolution is 0 1 up to 10 meters and 1 from 10 to 20 meters To set the system time delay push the delay encoder and rotate it until the wanted setting is displayed Push the encoder again to confirm the setting It is possible to create subwoofer cardioid...

Page 10: ...s the RDNet user settings last configuration saved BY PASS SWITCH released LED OFF the system reads the input board and bypass the user setting eventually loaded ion the speaker last configuration eventually saved TTS36 A DEFAULT CONFIGURATION The TTS36 A factory default configuration the configuration that the system reads if the BY PASS switch is pressed is the following Sensitivity 4 dBu High p...

Page 11: ...oated steel bars are provided on the back of the cabinet for fork lift transportation TRANSPORTATION WARNING Never suspend TT speakers by there handles Handles are intended for transportation not for rigging WARNING Always make sure that the maximum current requirement does not exceed the maximum admitted POWERCON current In case of doubt call the closest RCF service centre MAINS SUPPLY The system...

Page 12: ...y with Socapex SL 419 Series 13360145 AC POWER BOX 6XTTL55 EUROPEAN STAGE BOX TO POWER 6 TTL55 A LINE ARRAY MODULES OR 6 TTS36 A MODULES 1 piece for every 6 pieces of TTL55 and 1 piece for every 6 pieces of TTS56 SUB are suggested Full compatibility with Socapex SL 419 Series 13360146 AC POWER EXTENSION TTL55 POWER EXTENSION CABLE 20 meters AC power extension cable Full compatibility with Socapex ...

Page 13: ... es candele accese deve essere posta sull apparecchio 4 Non eseguire sul prodotto interventi modifiche riparazioni se non quelle espressamente descritte sul manuale istruzioni Contattare centri di assistenza autorizzati o personale altamente qualificato quando l apparecchio non funziona o funziona in modo anomalo il cavo di alimentazione è danneggiato oggetti o liquidi sono entrati nell apparecchi...

Page 14: ... monitor da studio sono in grado di produrre NOTE IMPORTANTI Per evitare fenomeni di rumorosità indotta sui cavi che trasportano segnali dai microfoni o di linea per esempio 0dB usare solo cavi schermati ed evitare di posarli nelle vicinanze di apparecchiature che producono campi elettromagnetici di forte intensità Cavi di rete Linee che alimentano altoparlanti PRECAUZIONI D USO Collocare il prodo...

Page 15: ...e sviluppo nonché di produzione ci permette di integrare perfettamente tutti gli ingredienti che compongono il sistema TT La filosofia progettuale della nuova serie TT si basa sulla volontà di offrire soluzioni tecniche e strumenti acustici di immediato utilizzo Fattori chiave sono la capacità di sostenere elevati livelli di potenza e di pressione sonora con grande efficienza Intensi livelli sonor...

Page 16: ...sa alto 24 dB ottava per diffusori satellite SENSIBILITÀ IN INGRESSO Controlla il livello del segnale in ingresso all amplificatore di potenza Il controllo varia da 10 dBu massima attenuazione alla sensibilità 2 dBu massimo guadagno in ingresso La sensibilità nella posizione centrale è 4 dBu livello nominale richiesto per ottenere la massima potenza dagli amplificatori XLOW CUT Questo pulsante for...

Page 17: ...gnale in ingresso L amplificatore è dotato di un circuito di limiter RMS Il limiter RMS serve a proteggere i trasduttori Se il circuito di protezione RMS è attivo il LED si accende con colore ROSSO Il diffusore non deve mai essere utilizzato con il LED ROSSO acceso in modo continuo operare a lungo con il led rosso acceso può causare danni al diffusore PULSANTE CARDIOID SET UP Questo pulsante una v...

Page 18: ...ei diffusori Infatti è buona regola che i diffusori amplificati e gli amplificatori in genere siano sempre le ultime apparecchiature ad essere accese dopo il montaggio e le prime ad essere spente alla fine dello spettacolo A questo punto potete accendere il diffusore e alzare il controllo di livello a seconda delle necessità Il ritardo è espresso in metri Le risoluzione del ritardo è di 0 1 fino a...

Page 19: ...da RDNet ultima configurazione salvata TASTO BY PASS rilasciato LED OFF il sistema legge la scheda ingressi e bypassa lea configurazione utente eventualmente caricata sul modulo ultima configurazione eventualmente salvata CONFIGURAZIONE DI DEFAULT TTS36 A La configurazione di default del modulo TTS36 A la configurazione che viene letta se RDNet non è presente ed il pulsante by pass è premuto è la ...

Page 20: ...ato posteriore del mobile per il trasporto con muletto TRASPORTO ATTENZIONE non sospendere mai il diffusore per mezzo delle maniglie Le maniglie sono state progettate per il trasporto del diffusore non per la sua sospensione ATTENZIONE assicurarsi sempre che la richiesta massima di corrente non superi la corrente massima ammessa dai connettori POWERCON In caso di dubbio contattare il centro assist...

Page 21: ...pex Serie SL 419 13360145 AC POWER BOX 6XTTL55 STAGE BOX EUROPEO PER ALIMENTARE 6 TTL55 A O 6 TTS36 A 1 pezzo ogni 6 moduli di TTL55 A o moduli TTS56 A Completa compatibilità con Socapex Serie SL 419 13360146 AC POWER EXTENSION TTL55 CAVO DI ESTENSIONE DELL ALIMENTAZIONE Cavo di estensione dell alimentazione di lunghezza 20 metri Completa compatibilità con Socapex Serie SL 419 ACCESSORI µ ...

Page 22: ...dware 30 120 Hz 143 dB 60 Hz 90 Hz 2 x 18 neodymium woofer 4 5 voice coil 2 x 2000 Watt digital amplifiers PFC switching power supply XLR male female Powercon male female Cat5 Ethercon Sensitivity Control 2 dBu 10 dBu X low cut X over selection Delay set up Cardioid setting RDNet bypass User settings RDNet High pass low pass equalisation Crossover output processing Fast limiter dynamic compressor ...

Page 23: ......

Page 24: ...34 Int 44 870 626 3142 e mail info rcfaudio co uk RCF France tel 33 1 49 01 02 31 e mail france rcf it RCF Germany tel 49 2203 925370 e mail germany rcf it RCF Spain tel 34 91 817 42 66 e mail info rcfaudio es RCF Belgium tel 32 0 3 3268104 e mail belgium rcf it RCF USA Inc tel 1 603 926 4604 e mail info rcf usa com ...

Reviews: