4

ENGLISH

1.

 

All the precautions, in particular the safety ones, must be read with special attention, as 

they provide important information.

2. 

Power supply from mains

a.  The mains voltage is sufficiently high to involve a risk of electrocution; install and 

connect this product before plugging it in.

b.  Before powering up, make sure that all the connections have been made correctly and 

the voltage of your mains corresponds to the voltage shown on the rating plate on the 
unit, if not, please contact your RCF dealer.

c.  The metallic parts of the unit are earthed through the power cable. An apparatus with 

CLASS I construction shall be connected to a mains socket outlet with a protective 
earthing connection.

d.  Protect the power cable from damage; make sure it is positioned in a way that it 

cannot be stepped on or crushed by objects.

e.  To prevent the risk of electric shock, never open this product: there are no parts inside 

that the user needs to access.

3.

 Make sure that no objects or liquids can get into this product, as this may cause a short 

circuit.
This apparatus shall not be exposed to dripping or splashing. No objects filled with liquid, 
such as vases, shall be placed on this apparatus. No naked sources (such as lighted candles) 
should be placed on this apparatus.

4. 

Never attempt to carry out any operations, modifications or repairs that are not expressly 

described in this manual.
Contact your authorized service centre or qualified personnel should any of the following 
occur:

the product does not function (or functions in an anomalous way).

- The power cable has been damaged.
- Objects or liquids have got in the unit.
- The product has been subject to a heavy impact.

5.

 If this product is not used for a long period, disconnect the power cable.

6.

 If this product begins emitting any strange odours or smoke, switch it off immediately 

and disconnect the power cable.

7.

 Do not connect this product to any equipment or accessories not foreseen.

For suspended installation, only use the dedicated anchoring points and do not try to hang 
this product by using elements that are unsuitable or not specific for this purpose. Also 
check the suitability of the support surface to which the product is anchored (wall, ceiling, 
structure, etc.), and the components used for attachment (screw anchors, screws, brackets 
not supplied by RCF etc.), which must guarantee the security of the system / installation 
over time, also considering, for example, the mechanical vibrations normally generated by 
transducers.
To prevent the risk of falling equipment, do not stack multiple units of this product unless 
this possibility is specified in the user manual.

8. RCF S.p.A. strongly recommends this product is only installed by professional 
qualified installers (or specialised firms) who can ensure correct installation 
and certify it according to the regulations in force.
The entire audio system must comply with the current standards and regulations 
regarding electrical systems.

9.

 Supports and trolleys. 

The equipment should be only used on trolleys or supports, where necessary, that are 
recommended by the manufacturer. The equipment / support / trolley assembly must be 

SAFETY

PRECAUTIONS

IMPORTANT

Summary of Contents for SUB 9004-AS

Page 1: ...OWNER MANUAL SUB 9007 AS SUB 9006 AS SUB 9004 AS ACTIVE HIGH POWER SUBWOOFERS...

Page 2: ......

Page 3: ...3 ENGLISH ITALIANO LANGUAGE 4 11...

Page 4: ...ur the product does not function or functions in an anomalous way The power cable has been damaged Objects or liquids have got in the unit The product has been subject to a heavy impact 5 If this prod...

Page 5: ...T NOTES To prevent the occurrence of noise on line signal cables use screened cables only and avoid putting them close to Equipment that produces high intensity electromagnetic fields Power cables Lou...

Page 6: ...es Subwoofers are equipped with a new generation of DigitalAmplifiers The result of this is very high output extremely low distortion and an incredible natural sound The amplifier features a solid mec...

Page 7: ...rs SIGNAL LED The signal indicator lights green if there is audio signal present on the main PRESET LED Pushing the encoder three times the preset indicator lights green Then rotate the encoder to loa...

Page 8: ...second time the rear encoder the delay LED will light up Now rotating the encoder clockwise it will be possible to delay the signal output of the speaker The delay is expressed in meter The delay will...

Page 9: ...conjunction with L1 L4 preset SE LOW PASS EXCLUDED Dedicated preset with 20 Hz High Pass and Low Pass excluded moved to 400 Hz LE LOW PASS EXCLUDED Dedicated preset with 20 Hz High Pass and Low Pass...

Page 10: ...cardioid systems using groups of three modules A group is made of three modules the group shall be made as follow 2 modules pointing in forward direction cardioid switch released 1 module pointing in...

Page 11: ...l prodotto interventi modifiche riparazioni se non quelle espressamente descritte sul manuale istruzioni Contattare centri di assistenza autorizzati o personale altamente qualificato quando l apparecc...

Page 12: ...re che i monitor da studio sono in grado di produrre NOTE IMPORTANTI Per evitare fenomeni di rumorosit indotta sui cavi che trasportano segnali dai microfoni o di linea per esempio 0 dB usare solo cav...

Page 13: ...ente naturale L amplificatore dotato di una robusta struttura di alluminio che non solo lo rende robusto durante il trasporto e gli urti ma assiste la dissipazione termica La sezione ingressi dotata d...

Page 14: ...gnale audio all ingresso XLR PRESET LED Premendo una terza volta l encoder il led PRESET si illumina Ruotando l encoder si carica il preset desiderato LED LIMITER L amplificatore dotato di un circuito...

Page 15: ...etri Il ritardo in passi da 0 1 metri per i primi 10 metri e in passi da un metro per i successivi Il massimo ritardo di 20 metri Premendo una terza volta l encoder posteriore si illumina il LED di pr...

Page 16: ...nuto salvataggio dei parametri in memoria Una volta salvati i parametri sono permanentemente in memoria possibile spegnere e riaccendere il diffusore i parametri rimangono comunque memorizzati Per res...

Page 17: ...prime ad essere spente alla fine dello spettacolo A questo punto potete accendere il diffusore e alzare il controllo di livello a seconda delle necessit PRIMA DI ACCENDERE IL DIFFUSORE INSTALLAZIONE...

Page 18: ...RMS CONNECTIONS Signal input output XLR RDNet Ethercon XLR RDNet Ethercon XLR RDNet Ethercon Power input output Powercon IN OUT Powercon IN OUT Powercon IN OUT PROCESSOR Controls Gain EQ Xover Phase...

Page 19: ......

Page 20: ...10307494 RevB www rcf it RCF S p A Via Raffaello Sanzio 13 42124 Reggio Emilia Italy Tel 39 0522 274 411 Fax 39 0522 232 428 e mail info rcf it...

Reviews: