RCF HD 6045EN User Manual Download Page 2

4

ENGLISH

IMPORTANT NOTES

Before connecting and using this product, please read this instruction manual carefully 
and keep it on hand for future reference. This manual is to be considered an integral part 
of this product and must accompany it when it changes ownership as a reference for 
correct installation and use as well as for the safety precautions.
RCF S.p.A. will not assume any responsibility for the incorrect installation and / or use of 
this product.

SAFETY AND OPERATING PRECAUTIONS
1. 

All the precautions, in particular the safety ones, must be read with special attention, 

as they provide important information.

2. 

Speaker lines (amplifier outputs) can have a sufficiently high voltage (i.e. 100-70 V) to 

involve a risk of electrocution: never install or connect this speaker when the line is alive.

3. 

Make sure all connections have been made correctly and the speaker input voltage is 

suitable for the amplifier output.

4. 

Protect speaker lines from damage. Make sure they are positioned in a way that they 

cannot be stepped on or crushed by objects.

5. 

Make sure that no objects or liquids can get into this product, as this may cause a 

short circuit.

6. 

Never attempt to carry out any operations, modifications or repairs that are not 

expressly described in this manual. 
Contact your authorized service centre or qualified personnel should any of the following 
occur:

 

-

The speaker does not function (or works in an anomalous way).

 

-

Its cable has been damaged.

 

-

Objects or liquids have got into the unit.

 

-

The speaker has been damaged due to heavy impacts or fire.

7. 

Should the speaker emit any strange odours or smoke, remove it from the line after 

having immediately switched the amplifier off.

8.

 Do not connect this product to any equipment or accessories not foreseen.

For suspended installation, only use the dedicated anchoring points and do not try to 
hang this speaker by using elements that are unsuitable or not specific for this purpose.
Also check the suitability of the support surface to which the product is anchored (wall, 
ceiling, structure, etc.) and the components used for attachment (screw anchors, screws, 
brackets not supplied by RCF etc.), which must guarantee the security of the system / 
installation over time, also considering, for example, the mechanical vibrations normally 
generated by transducers.

9. RCF S.p.A.

 strongly recommends this product is only installed by professional 

qualified installers (or specialised firms) who can ensure a correct installation and certify 
it according to the regulations in force.
The entire audio system must comply with the current standards and regulations 
regarding electrical systems.

10. 

Mechanical and electrical factors need to be considered when installing a 

professional audio system (in addition to those which are strictly acoustic, such as sound 
pressure, angles of coverage, frequency response, etc.).

IMPORTANT NOTES

SAFETY AND OPERATING PRECAUTIONS

Summary of Contents for HD 6045EN

Page 1: ...USER MANUAL MANUALE D USO HD 6045EN HORN SPEAKER IN COMPLIANCE WITH EN 54 24 STANDARD DIFFUSORE ACUSTICO A TROMBA CONFORME ALLA NORMA EN 54 24 ...

Page 2: ...f the following occur The speaker does not function or works in an anomalous way Its cable has been damaged Objects or liquids have got into the unit The speaker has been damaged due to heavy impacts or fire 7 Should the speaker emit any strange odours or smoke remove it from the line after having immediately switched the amplifier off 8 Do not connect this product to any equipment or accessories ...

Page 3: ...phase is to be respected speakers shall be connected respecting the amplifier polarity This is important when speakers are installed adjacent one another for instance in the same room 13 To prevent inductive effects from causing hum noise and a bad system working speaker lines should not be laid together with other electric cables mains microphone or line level signal cables connected to amplifier...

Page 4: ...use that prevents damage to the audio line due to heat on the speaker Steel bracket HD 6045EN horn loudspeakers can be easily aimed and used in sounds systems having large spaces for instance car parks football stadiums undergrounds factories warehouses etc and also in all environments that need high efficiency loudspeakers RCF S P A THANKS YOU FOR PURCHASING THIS PRODUCT WHICH HAS BEEN DESIGNED T...

Page 5: ...ed and experienced personnel having the technical know how or sufficient specific instructions to ensure that are made correctly and prevent any electrical danger To prevent any risk of electric shock do not connect speakers when the amplifier is switched on Before turning the system on check all connections and make sure there are no accidental short circuits The entire sound system shall be desi...

Page 6: ...speaker with suitable wall plugs having screws bolts passing through the ø 12 5 mm holes on its mounting bracket Aim the horn speaker to the listening area and fix its position by tightening the two bolts of its mounting bracket THERMAL FUSE CABLE CLAMP FIRE RETARDANT CABLE RCF CV210 CV215 CV225 NEXT SPEAKER PREVIOUS SPEAKER 0 COM 100 V 100 70 V 0 ...

Page 7: ...he total speaker power In sound systems for emergency purposes Voice Alarm systems only use fire retardant cables i e RCF CV210 CV215 or CV225 Speaker lines must be kept separated from mains cable microphone cables or others in order to avoid inductive phenomena may cause hum or noises Use speaker cables having twisted wires to reduce hum caused by inductive effects due to coupling with electromag...

Page 8: ...0 h 50 v fiberglass white 620 mm w 475 mm h 564 mm d 24 41 w 18 70 h 22 21 d 21 4 kg 46 4 lbs 23 6 kg 51 1 lbs 620 mm 24 41 564 mm 22 21 475 mm 18 70 1 Sensitivity is measured in full space free field with pink noise signal band limited 100 Hz 10 kHz without any equalization 1 W power 7 1 V on 50 Ω at 1 m distance 2 Max SPL average is measured as 1 but with 200 W power 100 V on 50 Ω maximum peak S...

Page 9: ...liant with EN 54 24 2008 one of the above equalization corrections shall be applied EQUALIZATION 5 6 Freq Hz Level dB 100 30 125 11 160 3 200 0 250 1 315 0 400 1 500 2 630 4 800 6 1000 9 1250 10 1600 9 2000 8 2500 6 3150 2 4000 3 5000 6 6300 7 8000 2 10000 11 Freq Hz Level dB BW Q 1200 10 1BW 1 414 6100 10 1BW 1 414 2500 6 1BW 1 414 ...

Page 10: ...rmany tel 49 2203 925370 e mail germany rcf it RCF Spain tel 34 91 817 42 66 e mail info rcfaudio es RCF Belgium tel 32 0 3 3268104 e mail belgium rcf it RCF USA Inc tel 1 603 926 4604 e mail info rcf usa com Except possible errors and omissions RCF S p A reserves the right to make modifications without prior notice Salvo eventuali errori ed omissioni RCF S p A si riserva il diritto di apportare m...

Reviews: