25
ENGLISH
FILTER
CONFIGURATION
LOW CROSSOVER
POINT
HIGH CROSSOVER
POINT
None
FTRL Off
FTRH Off
Highpass
FTRL not Off
FTRH Off
FRQL
Lowpass
FTRL Off
FTRH not Off
FRQH
Bandpass
FTRL not Off
FTRH not Off
FRQL FRQH
LIMIT -
OUTPUT LIMTER
OUT_1: XXXXXX MENU: Limit
THRESH: +20.0dBu
ATTACK: 100ms
RELEASE: 32x
• THRESH
- Limit Threshold. Ranges from -20 to +20dBu in 0.5dB steps.
• ATTACK
- Attack time. Ranges from 0.3 to 1ms in 0.1ms steps, then ranges from 1 to 100ms in
1ms steps.
• RELEASE
- Release time. It can be set at 2X, 4X, 8X, 16X or 32X the attack time.
SOURCE -
INPUT SOURCE
OUT_1: XXXXXX MENU: Source
1: On 4: Off
2:Off
3:Off
• 1,2,3,4
– Input channel source for the current output channel. it can be set to enable the input
source (On) or disable it (Off). If more than one input source are enabled, they will be added
together as the source for the current output channel.
CH-NAME -
CHANNEL NAME
OUT_1: XXXXXX MENU: Ch-Name
NAME: XXXXXX
•
Refer to the Input Menus for details