SAFETY AND OPERATING 

PRECAUTIONS

IMPORTANT NOTES

IMPORTANT NOTES

Before connecting and using this product, please read this instruction manual 
carefully and keep it on hand for future reference. This manual is to be 
considered an integral part of this product and must accompany it when it 
changes ownership as a reference for correct installation and use as well as 
for the safety precautions.
RCF S.p.A. will not assume any responsibility for the incorrect installation and 
/ or use of this product.

SAFETY AND OPERATING PRECAUTIONS
1. 

All the precautions, in particular the safety ones, must be read with special 

attention, as they provide important information.

2. 

Speaker lines (amplifier outputs) can have a sufficiently high voltage (i.e. 

100-70 V) to involve a risk of electrocution: never install or connect this 
speaker when the line is alive.

3. 

Make sure all connections have been made correctly and the speaker input 

voltage is suitable for the amplifier output.

4.

 Protect speaker lines from damage. Make sure they are positioned in a 

way that they cannot be stepped on or crushed by objects.

5. 

Make sure that no objects or liquids can get into this product, as this may 

cause a short circuit.

6. 

Never attempt to carry out any operations, modifications or repairs that 

are not expressly described in this manual. 
Contact your authorized service centre or qualified personnel should any of 
the following occur:

 

-

The speaker does not function (or works in an anomalous way).

 

-

The cable has been damaged.

 

-

Objects or liquids have got into the unit.

 

-

The speaker has been damaged due to heavy impacts or fire.

7. 

Should the speaker emit any strange smell or smoke, remove it from the 

line after having immediately switched the amplifier off.

8. 

Do not connect this product to any equipment or accessories not foreseen.

For suspended installation, only use the dedicated anchoring points and do 
not try to hang this speaker by using elements that are unsuitable or not 
specific for this purpose.
Also check the suitability of the support surface to which the product 
is anchored (wall, ceiling, structure, etc.) and the components used for 
attachment (wall plugs, screws, brackets not supplied by RCF, etc.), which 
must guarantee the security of the system / installation over time, also 
considering, for example, the mechanical vibrations normally generated by 
transducers.

Summary of Contents for DP 4EN

Page 1: ...USER MANUAL MANUALE D USO DP 4EN SPEAKER Sound projector in compliance with EN 54 24 standard DIFFUSORE ACUSTICO Proiettore sonoro conforme alla norma EN 54 24 ...

Page 2: ......

Page 3: ... ENGLISH SAFETY AND OPERATING PRECAUTIONS DESCRIPTION CONNECTION INSTALLATION SPECIFICATIONS ITALIANO AVVERTENZE PER LA SICUREZZA E PRECAUZIONI D USO DESCRIZIONE COLLEGAMENTO INSTALLAZIONE DATI TECNICI 4 6 6 8 8 10 12 12 14 14 ...

Page 4: ...ped on or crushed by objects 5 Make sure that no objects or liquids can get into this product as this may cause a short circuit 6 Never attempt to carry out any operations modifications or repairs that are not expressly described in this manual Contact your authorized service centre or qualified personnel should any of the following occur The speaker does not function or works in an anomalous way ...

Page 5: ...evels is being used it is necessary to wear ear plugs or protective earphones See the technical specifications in the user manual for the maximum sound pressure the speaker is capable of producing 12 To ensure a correct sound reproduction speaker phase is to be respected speakers are connected respecting the amplifier polarity This is important when speakers are installed adjacent one another for ...

Page 6: ...uring the installation It has a ceramic terminal strip inside its rear panel to connect in out cables Its thermal fuse prevents damages to the audio line due to excessive speaker heat Colour light grey DESCRIPTION CONNECTION Warning speaker connections should be only made by qualified and experienced personnel having the technical know how or sufficient specific instructions to ensure that connect...

Page 7: ...ective contact indicated on the ceramic terminal strip If speakers are connected to a 70 V line their power rates will be halved Notes Make sure all speakers are connected in phase to ensure a correct sound reproduction Always use cables having wires with an adequate cross section considering the cable length and the total speaker power Speaker lines must be kept separated from mains cable microph...

Page 8: ...peaker as described in the previous manual section Install the speaker through the 6 mm holes present on its mounting bracket Aim the speaker to the listening area and fix its position by tightening the two bolts of its mounting bracket INSTALLATION SPECIFICATIONS Input Nominal power Input impedance Transducer Frequency response Sensitivity Max sound pressure level Coverage angle Body material Gri...

Page 9: ......

Page 10: ...a dell amplificatore 4 Accertarsi che la linea diffusori non possa essere calpestata o schiacciata da oggetti al fine di salvaguardarne la perfetta integrità 5 Impedire che oggetti o liquidi entrino all interno del prodotto perché potrebbero causare un corto circuito 6 Non eseguire sul prodotto interventi modifiche riparazioni se non quelle espressamente descritte sul manuale d uso Contattare cent...

Page 11: ... per orecchie o delle cuffie protettive Consultare i dati tecnici contenuti nel manuale d uso per conoscere la massima pressione sonora che il diffusore acustico è in grado di produrre 12 I diffusori devono essere collegati in fase corrispondenza delle polarità tra amplificatori e diffusori in modo da garantire una corretta riproduzione audio soprattutto quando i diffusori sono collocati in posizi...

Page 12: ...n fase di installazione È presente una morsettiera ceramica all interno nel retro dotata di fusibile termico che evita di compromettere l integrità della linea audio a causa del calore che interessa il diffusore Colore grigio chiaro DESCRIZIONE COLLEGAMENTO Attenzione per il collegamento del diffusore si raccomanda di rivolgersi a personale qualificato ed addestrato avente conoscenze tecniche o es...

Page 13: ...imbolo di messa a terra Collegando il diffusore acustico ad una linea a tensione costante 70 V la potenza si dimezza Note Per garantire una corretta riproduzione audio effettuare il collegamento di tutti i diffusori in fase Utilizzare dei cavi con conduttori aventi una sezione adeguata considerando la loro lunghezza e la potenza complessiva dei diffusori Per evitare che fenomeni induttivi diano lu...

Page 14: ...mento come descritto nella sezione precedente del manuale Installare il diffusore alla parete o al soffitto tramite i fori con diametro 6 mm presenti sulla staffa del diffusore Orientare il diffusore verso l area d ascolto e bloccare la posizione serrando i due bulloni presenti alle estremità della staffa di fissaggio INSTALLAZIONE DATI TECNICI Ingresso Potenza nominale Impedenza d ingresso Altopa...

Page 15: ... voice alarm systems for fire detection and fire alarm systems for buildings All EN54 24 2008 standard requirements are verified in the RCF S p A manufacturing plant site in Via Raffaello Sanzio 13 42124 Reggio Emilia ITALY Tutti i requisiti di conformità alla normativa EN54 24 2008 sono verificati nello stabilimento produttivo di RCF S p A Via Raffaello 13 42124 Reggio Emilia ITALY ...

Page 16: ...Emilia Italy Tel 39 0522 274 411 Fax 39 0522 232 428 e mail info rcf it Salvo eventuali errori ed omissioni RCF S p A si riserva il diritto di apportare modifiche senza preavviso Except possible errors and omissions RCF S p A reserves the right to make modifications without prior notice ...

Reviews: