RC 401 REMOTE CONTROLS
RC 401 is a wall mount remote that works in combination with DMA units. It can be connected to each DMA power output and allows
adjusting the output volumes, muting them or selecting the desired input program.
When RC 401 is connected to a DMA unit, it is the only outputs volumes control, are the corresponding controls
in the DMA menu will be disabled.
RC 401 provides the following functions:
[A]
OUTPUT VOLUME CONTROL
. The knob adjusts the output volume in the range -36 dB ÷ +12 dB.
[B]
SELECT INPUT
. Allows to loop DMA unit inputs, with sequence IN 1 > IN 2 > BAL IN.
[C]
MUTE
. Mutes the DMA unit output volume.
RC 401 shall be connected on the rear panel of DMA units, with the dedicated removable screw terminal connectors.
-
It is possible to connect one RC 401 to each DMA unit power output.
-
The maximum distance between DMA unit and RC 401 is 50m.
-
Connection shall be done with CAT5 shielded cable.
Wiring schemes shown in Figure 1 and Figure 2 represent the configuration to implement the applications
described in the following tables.
Figure 1