Specifications
Electrical
DC Voltmeter:
Ranges
.
0 to 3, 12, 60, 300,
1
200 volt
s
I
n
put
R
es
i
s
t
ance
(Wi
t
h
Wit
h
W
G
·299B
s
witch
s
et to "
D
C":
All Ranges
.
11 m
e
g
o
hms
Accuracy:
W
i
t
h
Fu
n
ctio
n
Sele
ct
or
.
Set
o
n "
+
VO
L
TS"
±
3
% of f
u
ll s
c
a
l
e
W
i
t
h
Functi
o
n Selec
t
or Sct on
'
I
-
VOL
T
S"
±
5% of f
u
ll scale
AC Voltmeter:
Ra
ng
es
:
{ 0
to
3
v
olts on
.
...
.
().
.
.
s
e
p
arate
scale
~
0
t
o
1
2
,
6
0, 300
,
tAJP
120
0
volts
Acc
ur
acy
. .
. . .
.
.
.
.
-e
.
..
±
5
%
of full scale
Inpu
t
Res
i
s
t
ance and Ca
p
a
c
i
t
ance
-
Ap.p
r
ox
.
(with WG
-
299B
sw
itch
s
et t
o
"AC"
)
:
0
3
,
1
2
,
and 60
-
V Ranges ..
"
O
,,
2
~
ohm
shun
t
ed
b
y 75
µµf
3aO-V
Ra
n
g
e
1
m
e
gohm
s
hunted
by
5
0
µ
µ£
1
2
0
0-V Rang
e
2 m
e
gohms
s
hunted by 50
µµ£
F
r
e
quency
Re
s
pon
s
e (wi
t
h
WG-299B
s
witch set to
"
AC
"
)
:
For Sou
r
ce Impedanc
e
of 100 Ohrrts#
.
.
fl
at within
±
1 db
from 30 cps to
3 Me
,
,
RMS
V
alues o
f
Sine Waves.
Fo
r
So
u
rc
e
Impedance of 1000 Ohm
s#
.
.
.
flat within
±
1 db
from 30 cp
s
to
0
.
75 M
e
.
Wi
t
h Crystal-Diod
e Pr
ob
e
WG
-
2M
.&.
.
..
fl
a
t wi
t
hi
n
±
1
d
b
from
50
Kc
.
to
250 Me.
Maxi
m
um
Inpu
t
Voltag
e
s
:
C
omb
i
n
e
d
A
C Peak Voltage and DC
V
olta
ge
:
Wh
e
n
I
n
s
trum
e
nt i
s
S
e
t
u
p
to
Me
a
su
re
DC .
.
1
800 peak
v
olts
Wh
e
n Instr
u
ment is Se
t
up to Meas
u
re AC
:
3-
vo
lt.
1
2
-
volt, a
nd 60-
v
olt
r
a
nges
.
400 de volts
300
-
v
olt and 1200-volt ran
ge
s
.
600 d
e
volts·
Ohmmeter
:
R
ang
es,
fiv
e
.
0
t
o 1000
m
e
g
o
hms
C
e
nt
e
r-
S
ca
le
Values
1
0, 1000, 10000 ohm
s
, 1.0 megohm,
1
0 me
g
o
hms
Meter Movement:
DC Current
f
or Full·Sc
a
le Deflection.
200 µa
Tube C
o
mpleInent:
.
Pow
e
r Supply:
V
oltag
e
Rating
.
Freque
n
c
y
Ratin
g
.
C
onsumption
.
. . _
.
1 R
<ll\
-12
A
LS
,
1
RCA-1
2
A
U
7
1
05 to
1
25 volts
50 to
6
0 c
p
s
5 watt
s
approx
.
B
attery:
1.5-volt cell
.
RCA T
y
pe VS036
Me
c
hanical
Ov
e
r
-
a
ll
I
'
lei
g
ht
W
idth
Dep
th
Weight.
Dimensions
:
8
i
n
che
s
5
%
i
nches
4%
i
nc
h
es
4
pounds
#Th
e
f
r
e
qu
e
n
c
y
respons
e
s
h
o
w
n
i
s
f
o
r
o
nl
y
t
h
e
.~.
1
2
.
an
d
6
0
-
v
o
lt
r
ang
e
~
.
T
he
i
n
~
t
n
ll
nent
i
s a
c
c
urat
e
at
pnw
e
r
.lin
e
f
re
q
uenci
es
f
o
r all ran
ges
.
AA
v
a
ila
b
l
e
o
n
sepa
rat
e
orde
r.
*C
om
bin
e
d
AC P
ea
k
aud
D
C V
o
lta
ge
s
mu
s
t
n
o
t
e
x
ceed
1
8
0
0 v
o
lt
s
.
Operation
and Applications
....
...
<
Pre
li
min
i
ry
Adjust
m
ents:
To pre
p
a
r
e
tlie ·
\
VV
-
77C
fo
r
u
s
e
~
m
ake the f
o
llo
w
ing
con
n
ect
i
ons a
n
d adj us
t
rn
ents
:
1. Connect
t
h
e
WG-299BDC
/
AC
-
Ohms
Probe
and
Cab
l
e to the VOLTS OHMS
t
e
rm
i
n
al.
2
.
P
lu
g t
h
e power
c
or
d i
nto
a
n ac o
utl
et s
u
pp
l
y
i
ng
105
-
125 vo
lt
s
a
t
5
0
/
60 cycles, and ad
ju
st the con·
tr
o
I
s as
i
nd
i
c
a
ted be
l
ow:
a
.
T
u
rn t
h
e fu
n
c
t
ion select
o
r t
o
"
+
VOLTS" .
position,
a
nd allow sev
e
ral minutes fo
r
the
ins
trum
ent to w
ar
m
u
p
.
b
_
Ad
j
ust the ZERO ADJ co
nt
rol to positio
n
the
m
e
ter poi
n
ter at the
l
eft
-
ha
n
d
"
0"
.
NOTE: To
c
heck this adjustment,
noti
c
e w
h
e
th
er
or
n
ot the pos
i
t
i
on of the met
e
r pointer cha
n
ges
when
the
functio
n
s
el
e
cto
r
is
sw
i
tch
e
d
to
"
-
VOLTS
"
.
If
the p
oi
n
t
er
p
o
sit
i
o
n c
h
a
n
g
es,
readjust
the m
e
c
h
anica
l
ze
r
o c
on
t
r
o
l
a
s de-
scribed in th
e
Main
t
e
na
n
ce Sec
t
i
on.
c. T
u
rn
t
he fu
n
ct
i
on selecto
r
t
o
"
OHMS" posi-
t
i
o
n
.
The poi
n
te
r
s
h
ould de
fl
ect to
a
p
pr
oxi.
ma
.
tely f
u
ll s
cal
e.
d
.
Rotat
e
the OHMS ADJ co
ntr
ol
t
o pos
ition
the
po
i
nter a
t
t
h
e
l
ast line o
n
the "R" (
oh
ms)
scale
.
T
h
e
i
n
st
r
um
e
n
t
i
s now
r
eady
f
or
u
se
.
•
•
•
5
•
Summary of Contents for VoltOhmyst WV-77C
Page 13: ...I ...