Power Supply

SenSmart 2000

Loop Powered 10-30 VDC at <.75 watt

SenSmart 3000

Power Input 10-30VDC at < 6.5 watts with relay 

board (all relay energized)

4-20MA Output

SenSmart 2000

Standard 2-wire 4-20mA current sink . Max loop 

Resistance is 600 ohms with nominal

24VDC power supply

SenSmart 3000

3-wire 4-20mA current source. Max loop R is 750 

ohms with nominal 24VDC power supply

Output

SenSmart 2000

Standard 2-wire 4-20mA current sink . Max loop 

Resistance is 600 ohms with nominal

24VDC power supply

SenSmart 3000

Dual 3-wire 4-20mA current source. Max loop R is 

750 ohms with nominal 24VDC power

supply

Optional Output:

Dual isolated 4-20mA current source. Max loop 

Resistance is 650 ohms with nominal

24VDC; MODBUS slave ports; 3x programmable 

alarm relays with 5A capability

Enviornmental

ALL

Electronics -40°C to +60°C. See Electrochemical 

Sensor Manual for additional information

Approvals

SenSmart 2000

CSA Certified Div 1 & 2 Groups B, C, D. Suitable for 

explosion-proof installations

CSA Certified Div 1 & 2 Groups A, B, C, D for 

Intrinsically safe installations

SenSmart 3000 

 Cast Aluminum Enclosure:

Explosion-Proof Cl 1 Div 1 Gr ABCD with 10-0247 

(includes sinter)

Non-Incendive Cl 1 Div 2 Gr ABCD with 10-0247 or 

10-0247IS

UL94 Poly Black Plastic Enclosure:

Non-Incendive Cl 1 Div 2 Gr ABCD

Warranty

ALL

5  year  limited  warranty                                                                                                            

For sensor warranty see sensor specifications sheet.

SPECIFICATIONS

Sen

Smart 

2000/3000

Summary of Contents for 10-0234

Page 1: ...ide Flammable Toxic Gas Detectors Smart Alarm Controllers Fire Gas System Engineering Technical Service Support Warning Read understand contents of this manual prior to operation Failure to do so could result in serious injury or death ...

Page 2: ......

Page 3: ...ions B Remove windowed lid from unit 1 AL Enclosure unscrew lid and remove thumbscrew to access terminals 2 PY Enclosure unscrew 4 lid screws to access terminals C Remove thumb screws and pull display to the side Aluminum Enclosure Gas Detector Installation and Power up www rcsystemsco com GETTING STARTED 1 ...

Page 4: ...SenSmart 2000 3000 Figure 1 mounting dimensions Aluminium Polycarbonate ...

Page 5: ...onnect Common lead to TB2 4 See Figure 3 C Connect signal lead to TB2 2 Channel 1 4 20mA Out and or TB2 3 Channel 2 4 20mA Out See Figure 3 2 SenSmart 2000 A Connect the 10 30VDC 4 20mA loop wires to terminals TB1 1 and TB1 2 See Figure 2 Power Up Standard Output Installation GETTING STARTED ...

Page 6: ...Figure 3 SenSmart 3000 wiring SenSmart 2000 3000 Figure 2 SenSmart 2000 wiring ...

Page 7: ... Apply power to unit and observe power up screen C After the warm up period observe gas type and gas concentration on screen D Using appropriate magnet swipe Down Key on the display Follow on screen prompts to perform calibration check FINALIZE INSTALLATION 1 ...

Page 8: ...e SenSmart 3000 Manual for Communication Port setup B Relay Outputs 3 programmable 5A SPDT Relays RLY1 RLY2 and RLY3 see Figure 4 Refer to the SenSmart 3000 Manual for Communication Port Setup Figure 4 SenSmart 3000 Relay Modbus Option wiring 1 10 0234 SenSmart 3000 RS485 Modbus Relay Option SenSmart 2000 3000 OPTION INSTALLATION ...

Page 9: ...p powered gas detector for toxic and oxygen detection Includes a 4 20mA output SenSmart 3000 10 30VDC powered gas detector for toxic oxygen combustible VOC and CO2 detection This model adds a backlit LCD display and has Modbus and or 4 20mA communications and relays available SenSmart 3000 ...

Page 10: ...ptional Output Dual isolated 4 20mA current source Max loop Resistance is 650 ohms with nominal 24VDC MODBUS slave ports 3x programmable alarm relays with 5A capability Enviornmental ALL Electronics 40 C to 60 C See Electrochemical Sensor Manual for additional information Approvals SenSmart 2000 CSA Certified Div 1 2 Groups B C D Suitable for explosion proof installations CSA Certified Div 1 2 Gro...

Page 11: ......

Page 12: ...nical support from experts right here in our local facility If you are in need of any assistance during the setup of this product you may contact our main office and your call will be directed appropriately At R C Systems we are proud to supply quality products and are happy to help if you have any questions or concerns MM 1061 ...

Reviews: