1 2 3 4 5
Small overall dimensions,
depth of built-in box
adjustable from 8 to 10 cm.
QUICKBOX box
Positioning with easy fastening
1
(GB)
After choosing the most suitable position and making an
opening in the wall for inserting the box, use the middle brack-
ets (bring them to the end stop until they click) to position the
edge of the box at a distance of 1 cm from the hollow brick.
This distance corresponds to the thickness of the plaster.
These brackets will make it possible to align and to fix the bot-
tom of the box to the wall temporarily using nails or screws.
N.B.
If a connecting hole is drilled, it is possible to use the
grids on the bottom of the box to let the mortar set.
(GB)
Afterwards apply rapid cement onto the 4 brackets, on
the corners and onto the setting grids placed on the bottom
of the box in order to fix the box firmly to the wall.
Before carrying out these operations, mount the protection
supplied to prevent the inside of the box from getting dirty.
2
Assembly and connection
(GB)
Fix the manifold groups (delivery and return) using
the moving clips placed in the guides which when neces-
sary can be moved to right or left for correct positioning.
A
A
B
B
(GB)
To facilitate the connection of secondary pipe-
work to the manifolds, the upper profile at the base
of the box must be removed. This will make it pos-
sible to insert the “extractable” masonry protections.
C
(GB)
If the opening of the wall is a through opening, the
protection supplied must be mounted behind the second-
ary pipework.
B
4
Masonry protection shell
(GB)
When the system is con-
nected, close the compartment
of the box using the specific
protection, before plastering the
unfinished wall.
5
Installation of the cover
(GB)
When the wall
rendering is completed,
fix the cover using the
standard RBM screws
supplied.
A
A
(GB)
Partitioning element 8 cm.
(GB)
1 cm plaster on both sides.
A
C
B
!
!
(GB)
Removable mortar setting grid (thickness
2.5 mm.) (fastening with anchorage teeth).
Available dimension:
55
,
70
and
85
cm
C
C
Positioning and coupling
3
Positioning layout of the
terminal manifold group
inside the box, using
brackets
(GB)
Place the dovetail guide of the brackets in the open-
ings made on the bottom of the box (1). Then simply move
the manifold group to the right in order to fix it to the box,
using brackets.
A
B
C
8 cm
1 cm
Description
Examples of coupling between manifold
kits and the box
!
A
B
1
2
Manifold Polymers
Brass Manifold
LAYOUT OF THE
OPENINGS
NUMER OF
TERMINALS
Four slits for the inser-
tion of the collectors in
the guides to accom-
modation worthless
ball and exhaust unit
70
cm
BOX
ASSEMBLY INSTRUCTION
1
3
4
5
6
7
8
11
10
9
12
2
1
Upper protection for secondary
pipework
7
Wall protection
2
Bottom protection for secondary
pipework
8
Cover
3
Terminal plate for wall mounting
and positioning
9
Fixing screws for
cover
4
Key for opening/closing the
cover
10
Lower bracket
5
Removable net for allowing the
mortar to set
11
Higher bracket
6
Base
12
Bracket screws for
manifolds fixing