background image

CA-200

Discrete Class A/B Subwoofer Amplifier
200 Watts RMS @ 4 Ohms
<.04% @ 1 Watt 
>82dB (without filter)
45 Kohms
200 Ohms
80 mV
2.8V
12dB/Octave
40-180Hz ±dB
2 mV @ 50 Hz
20Hz-40kHz ±3dB (filter off)
4dB @ 25Hz
>200
Black Metal Alloy
10” W x 10” H x 5.75” D 

(482mm W x 101mm H x 355mm D)
14 lbs. (6.35 kg)
1 year

Model:

Amplifier Type:
Power Output:
Distortion (THD):
S/N Ratio:
Line Level Input Impedance:
Speaker Level Input Impedance:
Line Level Input Sensitivity:
Speaker Level Input Sensitivity:
Crossover Slope:
Crossover Freq. Range:
Auto Turn-on Sensitivity:
Frequency Response:
Boost:
Damping Factor: 
Cabinet Material and Finish: 
Dimensions:  

Weight: 
Warranty: 

No sound from  

subwoofer. 

 

 

 

Performance 

is less than 

expected.

Amplifier is not connected to constant 

power outlet. 

Amplifier is not receiving an audio  

signal from receiver or processor.
Amplifier fuse might be blown. 

 

The + and - polarity of the subwoofer 

wire might be reversed on the  

subwoofer.
Crossover frequency not adjusted  

correctly. 

 

L/R line level input is connected 

instead of the LFE line level input.

Troubleshooting

Probable Cause:

Situation:

Make certain the amplifier is 

plugged into an unswitched AC 

power outlet.
Make certain there is an audio sig-

nal from receiver or processor.
Replace fuse (if fuse is not readily  

accessible, consult your authorized 

RBH Sound dealer).
Check the entire system for proper 

polarity. Experiment with the phase 

switch settings. 
Adjust the crossover frequency by 

turning the crossover frequency  

control clockwise until the desired 

sound is obtained.
If  bass  management  is  enabled  on 

receiver  or  processor  make  sure  to 

use the LFE line level input. (See the 

Amplifier Controls and Setup section of 

Solution:

Specifications

4

Summary of Contents for CA-200

Page 1: ...O w n e r s M a n u a l CA 200 Subwoofer Amplifier ...

Page 2: ......

Page 3: ...ain this user manual for future reference 3 Follow all warnings and instructions in this manual and any marked on the back of the amplifier 4 The amplifier should be connected to a power supply compatible with the power consumption requirements see the specifications section of this manual 5 If mounting the amplifier on a stand the wall or other device only do so as recommended by an RBH Sound aut...

Page 4: ...ly deeper bass NOTE Read the Important Notice above regarding bass management 4 Auto Signal Tracking The amplifier uses smart signal tracking circuitry Once the power cord is plugged in and the switch set to auto the amplifier automatically turns on when a signal is detected at the preamplifier or high level inputs and turns off when no signal has been detected for 15 minutes 5 Phase Control This ...

Page 5: ...equencies below 100 Hz from going to your satellite main speakers This crossover is active only when using the High Level Input terminals Connect your main speakers observing the proper polarity to these terminals when using the High Level Inputs 11 Fuse Access This is the power fuse access WARNING In the event the fuse must be replaced the replacement fuse must match exactly the original fuse val...

Page 6: ...t Amplifier is not receiving an audio signal from receiver or processor Amplifier fuse might be blown The and polarity of the subwoofer wire might be reversed on the subwoofer Crossover frequency not adjusted correctly L R line level input is connected instead of the LFE line level input Troubleshooting Probable Cause Situation Make certain the amplifier is plugged into an unswitched AC power outl...

Page 7: ......

Page 8: ... alteration misuse or neglect RBH Sound assumes no liability for property damage or any other incidental or consequential damage whatsoever which may result from the failure of this product Any and all warranties of merchantability and fitness implied by law are limited to the duration of this express warranty Some states do not allow limitations on how long an implied warranty lasts so the above ...