![RBH Access Technologies UNC100 Manual Download Page 2](http://html.mh-extra.com/html/rbh-access-technologies/unc100/unc100_manual_792244002.webp)
Output
1
Lock “A”
Output
2
Alarm shunt “A”
Output
3
Output
4
Output
5
Lock “B”
Output
6
Alarm shunt “B”
Output
7
Output
8
1 2 3 4 5 6 7 8
IRC-2000-5
1
58
JP1
JP2 JP3 JP4
P1
Outputs 1- 4
P2
Outputs 5 - 8
P3
Reader
A
P4
Reader B
P5
Inputs 1- 4
P6
Inputs 5 - 8
P7
P8
P9
IRxxxxxxx
LED1
LED2
LED3 LED4
All jumpers off, change
only with tech support!
RS-485 BIAS
RS-232
RS-485
JP1
UP
if connector
P7
is
USED
JP1
DOWN
if
NOT
(Default)
Use
RS-232
Cable on
P7
to connect to a Serial port
on PC or
LIF200
Network
Module, 50’ Max.
Verify it matches your
software, up/downgrade
as needed via Firmware
Upgrade Utility
FIRMWARE
Use
Axiom Lite
software to check
firmware version
RX TX
See LED function
table below
Board model #
Serial #
Panel LEDs LED1 (Red) LED2 (Red)
LED3 (Red)
LED4 (Green)
FUNCTION Door forced
Host
Receive
Transmit
OFF
No
Power is off Host not polling Panel not responding
ON SOLID
Yes
Online
Malfunction
Malfunction
BLINKING
Card read
Offline
Receiving
Transmitting
Cycle power for DIP-switch changes to take effect!
A+ B- GND
Link up to 16 panels via RS-485
To
12 VDC 7 Ah
Rechargeable Battery
0VDC @ 2A
+12VDC @ 2A
PS-1224 Power Supply
BA
T.
TEST
Press “BAT. TEST” button on
PS-1224 for battery test, Yellow
LED will go ON if test failed
16.5VAC 40Va
16.5VAC 40Va
+ -
DCD
GND
RX
TX
1
C
2
3
C
4
RTE
“A”- Request to Exit
DC
“A” - Door contact
RTE
“B”- Request to Exit
DC
“B” - Door contact
5
C
6
7
C
8
GRN
RED
BUZ
D0
D1
TMP
0V
12V
LED
(For single LED readers)
Buzzer
Data 0
Data 1
0V, Power, Data Ground
+12VDC
LED
(For single LED readers)
Buzzer
Data 0
Data 1
0V, Power, Data Ground
+12VDC
GRN
RED
BUZ
D0
D1
TMP
0V
12V
N.O.
N.C.
COM
N.O.
N.C.
COM
OC
OC
Lock
Power
Supply
12-24 VDC
N.O.
N.C.
COM
N.O.
N.C.
COM
OC
OC
20-22 AWG Twisted, Shielded Pair. 4,000’ Max
Relay
Output 1
5A@30V
Relay
Output 2
5A@30V
Relay
Output 5
5A@30V
Relay
Output 6
5A@30V
Switch
1
2
3
4
5
Panel
1
On
Panel
2
On
Panel
3
On On
Panel
4
On
Switch
1
2
3
4
5
Panel
9
On
On
Panel
10
On
On
Panel
11
On On
On
Panel
12
On On
Switch
1
2
3
4
5
Panel
13
On
On On
Panel
14
On On On
Panel
15
On On On On
Panel
16
On
Switch
1
2
3
4
5
Panel
5
On
On
Panel
6
On On
Panel
7
On On On
Panel
8
On
Switch
6
7
9.6 K
19.2 K On
38.4 K
On
56 K On On
Switch 8: Always OFF!
12V 0V
THIS DOCUMENT IS FOR QUICK REFERENCE ONLY, REFER TO HARDWARE & SOFTWARE MANUALS FOR FULL DETAILS
RS-232 to PC or LIF-200
Panel LEDs
Power Supply (PS-1224) LEDs
DIP SWITCH SETTINGS : DIP-Switch: UP = ON / DOWN = OFF
DB9
RBH Cable
Pin 5 - GND
Red
Pin 3 - TX
Brown
Pin 2 - RX
Black
50’ Max
Shielded Cable Only
P7
P8
iButton
LED
On
Off
Green LED
Power On
Power Off
Red LED
Shorted
OK
Yellow LED Battery Fail Battery OK
Lock
+
Diode 1N4004
White stripe to +
-
For Support Call :
01386 425810
All software and hardware manuals are included
!
on
Axiom Lite
software CD in “Documents” folder
Web site : www.rbh
securitygroup.com
E-mail : support
.uk
@rbh-access.com
IRC-2000
I
ntelligent
R
eader
C
ontroller
with ENCL1 enclosure
and PS-1224 power supply
Lock
Power
Supply
12-24 VDC
+
-
Lock
Reader Shielding
Refer to hardware manual
Communications Shielding
Refer to hardware manual
Reader Color code
Refer to reader manual
Voltage (O
pen
C
ollector
) Outputs
-12VDC@100mA Max
Voltage (O
pen
C
ollector
) Outputs
Install diodes for rated relays
Belden 9538 cable for Readers
Belden 9538 cable for Readers
Belden 8723 cable for data
Belden 9538 cable for readers and Belden 8723 cable for data between panels