RBH Access Technologies UNC100 Manual Download Page 2

Output 

Lock “A”

Output 

Alarm shunt “A”

Output 

3

Output 

4

Output 

Lock “B”

Output 

Alarm shunt “B”

Output 

7

Output 

8

1  2  3  4  5  6  7  8

IRC-2000-5

1

58

JP1

JP2  JP3 JP4

P1     

Outputs 1- 4

P2     

Outputs 5 - 8

P3      

Reader 

A

P4      

Reader B

P5  

Inputs 1- 4

P6  

Inputs 5 - 8

P7

P8

P9

IRxxxxxxx

LED1

LED2

LED3   LED4

All jumpers off, change 

only with tech support!

RS-485 BIAS

RS-232

RS-485

JP1 

UP

 

if connector 

P7

 

is 

USED

JP1 

DOWN

if 

NOT

 (Default)

Use 

RS-232

 Cable on 

P7

 

to connect to a Serial port 

on PC or 

LIF200

 Network 

Module, 50’ Max.

Verify it matches your 

software, up/downgrade 

as needed via Firmware 

Upgrade Utility

FIRMWARE

 

Use 

Axiom Lite

 

software to check 

firmware version

RX       TX

See LED function 

table below

Board model #

Serial #

Panel LEDs  LED1 (Red) LED2 (Red)

LED3 (Red)

LED4 (Green)

FUNCTION Door forced

Host

Receive

Transmit

OFF

No

Power is off Host not polling Panel not responding

ON SOLID

Yes

Online

Malfunction

Malfunction

BLINKING

Card read

Offline

Receiving

Transmitting

Cycle power for DIP-switch changes to take effect!

A+  B-  GND

Link up to 16 panels via RS-485

To 

12 VDC 7 Ah

Rechargeable Battery

0VDC @ 2A

+12VDC @ 2A

PS-1224 Power Supply

BA

T. 

TEST

Press “BAT. TEST” button on 

PS-1224 for battery test, Yellow 

LED will go ON if test failed

16.5VAC 40Va
16.5VAC 40Va

+ -

DCD 

GND

RX

TX

1

C

2

3

C

4

RTE

 “A”- Request to Exit

DC

 “A” - Door contact

RTE

 “B”- Request to Exit

DC

 “B” - Door contact

5

C

6

7

C

8

GRN

RED

BUZ

D0

D1

TMP

0V

12V

LED 

(For single LED readers)

Buzzer
Data 0 
Data 1

0V, Power, Data Ground
+12VDC

LED 

(For single LED readers)

Buzzer
Data 0
Data 1

0V, Power, Data Ground
+12VDC

GRN

RED

BUZ

D0

D1

TMP

0V

12V

N.O.

N.C.

COM

N.O.

N.C.

COM

OC

OC

Lock

 

Power 

Supply

12-24 VDC

N.O.

N.C.

COM

N.O.

N.C.

COM

OC

OC

20-22 AWG Twisted, Shielded Pair. 4,000’ Max

Relay

Output 1

5A@30V

Relay

Output 2

5A@30V

Relay

Output 5

5A@30V

Relay

Output 6

5A@30V

Switch

1

2

3

4

5

Panel 

1

On

Panel 

2

On

Panel 

3

On On

Panel 

4

On

Switch

1

2

3

4

5

Panel 

9

On

On

Panel 

10

On

On

Panel 

11

On On

On

Panel 

12

On On

Switch

1

2

3

4

5

Panel 

13

On

On On

Panel 

14

On On On

Panel 

15

On On On On

Panel 

16

On

Switch

1

2

3

4

5

Panel 

5

On

On

Panel 

6

On On

Panel 

7

On On On

Panel 

8

On

Switch

6

7

9.6 K

19.2 K On
38.4 K

On

56 K On On

Switch 8: Always OFF!

12V   0V

THIS DOCUMENT IS FOR QUICK REFERENCE ONLY, REFER TO HARDWARE & SOFTWARE MANUALS FOR FULL DETAILS

RS-232 to PC or LIF-200

Panel LEDs

Power Supply (PS-1224) LEDs

DIP SWITCH SETTINGS : DIP-Switch:  UP = ON  /  DOWN = OFF

DB9

RBH Cable

Pin 5 - GND

Red

Pin 3 - TX

Brown

Pin 2 - RX

Black

50’ Max 

Shielded Cable Only

P7

P8

iButton

LED

On

Off

Green LED

Power On

Power Off

Red LED

Shorted

OK

Yellow LED Battery Fail Battery OK

Lock

+

Diode 1N4004

 

White stripe to +

-

For Support Call :

 

01386 425810

All software and hardware manuals are included 

!

on 

Axiom Lite 

software CD in “Documents” folder

Web site : www.rbh

securitygroup.com

   E-mail : support

.uk

@rbh-access.com 

IRC-2000

I

ntelligent 

R

eader 

C

ontroller

with ENCL1 enclosure

and PS-1224 power supply

Lock

 

Power 

Supply

12-24 VDC

+

-

Lock

Reader Shielding

 

Refer to hardware manual

Communications Shielding

 

Refer to hardware manual

Reader Color code

 

Refer to reader manual

Voltage (O

pen

 C

ollector

) Outputs

-12VDC@100mA Max

Voltage (O

pen

 C

ollector

) Outputs

Install diodes for rated relays

Belden 9538 cable for Readers

Belden 9538 cable for Readers

Belden 8723 cable for data

Belden 9538 cable for readers and Belden 8723 cable for data between panels

Reviews: