background image

6

Leaving the bath

When the bather is ready to leave the bath they should sit upright and ensure a central seating position is achieved within the coloured anti-slip seating area of
the cushion*. This position will ensure maximum safety during the inflate cycle. Taking the hand control unit in either hand de press the up button. The cushion
will slowly inflate to bring the bather back level with the top edge of the bath. Continue to depress the button until the blower stops automatically. During the
inflate cycle the bather should use the grab rail to improve balance. In addition the bather may also find it useful to rest one or both hands on the sides of the
bath to further aid balance.
The bather can now exit the bath by either swinging the legs over the bath, moving sideways off the cushion
or by stepping over and out of the bath.

Disconnecting

Please ensure the electrical supply is switched off and the green indicator light on the blower unit is off.

THE EQUIPMENT SHOULD NOT BE LEFT UNATTENDED WHILST CONNECTED TO THE ELECTRICITY SUPPLY, AND THE BLOWER
UNIT LEFT RUNNING FOR AN EXTENDED PERIOD.

After use the cushion should be deflated, at least partially to help remove it from the bath. To avoid putting undue strain on the cushion or suckers, the cushion
should be removed from the bath by lifting the sucker release tabs. Do not pull the cushion (see diagram D).
To fully deflate the cushion for storage simply disconnect the hose from the blower unit by depressing the button on the top ofthe
connector and pulling it away from the blower. This will allow most of the air to flow quickly out of the cushion. To remove the last
of the air, apply gentle pressure to the cushion or roll the cushion into a cylinder, starting with the end furthest away fromthe
hose.

Cleaning

The hand control unit, hose and cushion should be dried after use. In situations where there is a risk of passing infection, these
components should be sanitised with water based disinfectants rinsed and thoroughly dried. It is particularly important to store
the cushion dry.
The screw fixing suckers can be removed individually to be cleaned and then replaced.

D

Getting into the bath - continued

*IMPORTANT
A central sitting position on the cushion is vital whilst being raised or lowered. Leaning forwards slightly will help maintainstability. Please do not lean
backwards as this may result in an uneven descent or elevation. Should this occur during the deflate or inflate cycle, the bather should simply stop the cycle
using the hand control and re-position so they are seated within the coloured seating area, before continuing.

UK RBF Bath buddy instruction 16pp  21/9/07  09:07  Page 7

Summary of Contents for Bathmate

Page 1: ...Bath Buddy Bathmate Instruction Book UK RBF Bath buddy instruction 16pp 21 9 07 09 07 Page 1...

Page 2: ...afety Setting up and putting cushion in bath Filling and getting into bath Leaving bath disconnecting and cleaning Technical specification Trouble shooting guide Routine maintenance and servicing Note...

Page 3: ...en supervision or instruction concerning use of the appliance by a person responsible for their safety and understands the hazards involved This appliance can be used by children aged from 8 years or...

Page 4: ...n o i h s u c e t i h W 1 e d i u g g n i t a r e p o y d n a H 8 t i n u r e w o l b n i a M 2 d r a c e e t n a r a u G 9 s r e k c u s e t i h w 4 3 0 1 e s o h e t i h W 4 Electrical installation...

Page 5: ...wiring of the blower unit within the bathroom must comply with the current safety standards the procedures described in the enclosed installation instructions for hard wiring This appliance required...

Page 6: ...surface to check this pull gently on each sucker to establish adhesion 2 Switch on the power at the mains supply checking the green light on the blower unit is illuminated 3 Take the hand control uni...

Page 7: ...ction to continue depress the button again maintaining contact until right at the bottom of the bath To aid stability a fixed grab rail should be used with the Bath Buddy If a grab rail is not availab...

Page 8: ...the cushion or suckers the cushion should be removed from the bath by lifting the sucker release tabs Do not pull the cushion see diagram D To fully deflate the cushion for storage simply disconnect...

Page 9: ...e s u F Mode of Operation ED 10 Drive time to 2 mins Stop time to 18 mins s n o i t i d n o C g n i t a r e p O s n o i t i d n o C e g a r o t S t r o p s n a r T Temperature 20 to 50 Deg C Temperatu...

Page 10: ...a replacement cushion DO NOT USE Return for replacement cushion Air must be forced out of the cushion disconnect the hose from the blower unit this will allow most of the air to flow out of the cushio...

Page 11: ...tion on page 2 4 For maintenance and servicing within the public sector i e Hospitals and Nursing Homes please contact your local dealer or RBF Healthcare for an information sheet Accessories Spares S...

Page 12: ...therefore safe to be operated by either useror attendant with wet hands The blower unit however is connected to the mains electricity and should not be handled with wet hand unless disconnected from t...

Page 13: ...to whether a tall or standard cushion is required please refer to the diagram below If a bath falls outside of the guidelines below please contact your dealer or manufacturer for advice Both Standard...

Page 14: ...with the manufacturers specifications All dimensions are approximate and are for reference only The grab rail should always be fitted to suit the individual needs of the user A B Fitting Zone Fitting...

Page 15: ...emitting from the cushion or hose discontinue use contact your supplier 5 Should the blower unit casing cushion or hose become damaged please discontinue contact your supplier RBF Healthcare undertake...

Page 16: ...dy instruction 16pp 21 9 07 09 08 Page 16 RBF Healthcare 55 Vanguard Way Shoeburyness Essex SS3 9QY Tel 44 0 1702 527 401 Fax 44 0 1702 420 240 Email Sales rbfhealthcare co uk Why not visit our Websit...

Reviews: