razberi technologies
™
6
2.
Camera Cabling
Please follow the instructions below to complete LP500-360 connection.
2.1
Connect Power
Please refer to
Section: Connectors
. Alternatively, connect the Ethernet cable to
the camera’s RJ-45 port and plug the other end of the cable into a PoE switch.
NOTE:
If using PoE, make sure Power Sourcing Equipment (PSE) is in
use in the network.
2.2
Connect Ethernet Cable
Use of Category 5 Ethernet cable is recommended for the network connection.
Cable length shall not exceed 100 meters. Connect one end of the Ethernet
cable to the RJ-45 connector of the LP500-360, and the other end of the cable
to the network switch, PC or Razberi ServerSwitch.
NOTE:
In some cases, you may need use an Ethernet crossover cable
when connecting the LP500-360 directly to the PC.
Check the status of the link indicator and activity indicator LEDs; if the LEDs are
unlit, please check LAN connection.
Green Link Light indicates good network connection.
Orange Activity Light flashes for network activity indication.