Installation
2–14
F232097R1
Drain Connection
(Continued)
Before any deviation from specified
installation procedures is attempted,
the customer or installer should contact
the distributor.
Increasing the drain hose length, installing
elbows, or causing bends will decrease drain
flow rates and increase drain times, impairing
machine performance.
See the Cabinet Hardmount Drain Information
table below for capacity-specific drain
information.
Installation of additional machines will require
proportionately larger drain connections. See
the Cabinet Hardmount Drain Line Sizing
table below.
Cabinet Hardmount Drain Information
125-Pound Capacity Models
Drain connection size, ID, in/mm
3 / 76
Number of drain outlets
1
Drain flow capacity, gal-min/l-min
50 / 189
Recommended drain pit size, ft
3
/l
5.90 / 169
Drain center line height from floor, in/mm
13 / 330
Cabinet Hardmount Drain Line Sizing
125-Pound Capacity Models
Minimum Drain I.D. (in/mm)
Number of Machines
Drain Line Size
1
4 / 102
2
6 / 152
3
6 / 152
4
8 / 203
5
8 / 203
Summary of Contents for SC125VNV
Page 11: ...1 8 NOTES F232097R1 Safety ...
Page 15: ...Installation 2 4 F232097R1 ...
Page 33: ...Installation 2 22 F232097R1 ...
Page 43: ...3 10 NOTES F232097R1 Maintenance ...
Page 45: ...4 2 NOTES F232097R1 Removal from Service ...
Page 56: ...1 8 NOTAS F232097R1 SP Seguridad ...
Page 59: ...2 3 Instalación F232097R1 SP ...
Page 77: ...2 21 Instalación F232097R1 SP ...
Page 87: ...3 10 NOTAS F232097R1 SP Mantenimiento ...
Page 89: ...4 2 NOTAS F232097R1 SP Para poner fuera de servicio ...